Loading...
HomeMy WebLinkAbout2025-09-03 Agenda Packet Meeting Location: Municipal Center 7100 147th Street West Apple Valley, Minnesota 55124 September 3, 2025 Planning Commission Tentative Agenda 7:00 PM 1. Call To Order 2. Approve Agenda 3. Consent Agenda Consent Agenda Items are considered routine and will be enacted with a single motion, without discussion, unless a commissioner or citizen requests to have any item separately considered. It will then be moved to the regular agenda for consideration. A. Approve Minutes of August 6, 2025 Regular Meeting 4. Public Hearings 5. Land Use / Action Items A. Valley Station Apartments - PC25-13BGZ Consider Planned Development Amendments & Site Plan/Building Permit Authorization to allow construction of 144-unit apartment building. LOCATION: 15584 Gaslight Drive APPLICANT: Real Estate Equities 6. Other Business A. Review of Upcoming Schedule and Other Updates Planning Commission - Wednesday, September 17, 2025 - 7:00 p.m. Planning Commission - Wednesday, October 1, 2025 - 7:00 p.m. City Council - Thursday, September 11, 2025 - 7:00 p.m. City Council - Thursday, September 25, 2025 - 7:00 p.m. 7. Adjourn Regular meetings are broadcast, live, on Charter Communications Cable Channel 180 and on the City's website at www.applevalleymn.gov ITEM: 3.A. MEETING DATE: September 3, 2025 SECTION: Consent Agenda Description: Approve Minutes of August 6, 2025 Regular Meeting Staff Contact: Breanna Vincent, Department Assistant Department / Division: Community Development Action Requested: Approve minutes of the regular meeting of August 6, 2025. Summary: The minutes of the regular Planning Commission meeting is attached for your review and approval. Background: State statute requires the creation and preservation of meeting minutes which document the official actions and proceedings of public governing bodies. Budget Impact: N/A Attachments: 1. 080625 PC MINUTES CITY OF APPLE VALLEY PLANNING COMMISSION MINUTES August 6, 2025 1. CALL TO ORDER The City of Apple Valley Planning Commission Meeting was called to order by Chair Kurtz at 7:00 p.m. Members Present: Jodi Kurtz, Paul Scanlan, Dave Schindler, Phil Mahowald, and Douglas Hlas Member(s) Absent: Becky Sandahl, Jeff Prewitt City Staff: Community Development Director Tim Benetti, Associate Planner Sydnee Stroeing, City Attorney Sharon Hills, and Department Assistant Breanna Vincent. 2. APPROVAL OF AGENDA Chair Kurtz asked if there were any changes to the agenda CD Director Benetti stated that there is an updated resolution to item 5. A. provided to commissioners. MOTION: Commissioner Mahowald moved, seconded by Commissioner Hlas, approving the agenda. Roll call vote: Ayes - 5 – Nays – 0. 3. CONSENT ITEMS A. Approval of Minutes of July 16, 2025 MOTION: Commissioner Scanlan moved, seconded by Commissioner Schindler approving the minutes of July 16, 2025. Roll call vote: Ayes - 5 – Nays – 0. 4. PUBLIC HEARING A. Planned Development No. 1144 (PD-1144) Setback Amendment Chair Kurtz opened the public hearing. Associate Planner Stroeing provided a brief presentation. Commissioner Hlas asked if the developer of the apartments will be constructing the walking path on the northern side and then the City will be maintaining it. CITY OF APPLE VALLEY Dakota County, Minnesota Planning Commission Minutes August 6, 2025 Page 2 of 3 Associate Planner Stroeing stated that was correct. With no further comments, Chair Kurtz closed the public hearing. MOTION: Commissioner Scanlan moved, seconded by Commissioner Schindler, to recommend approval of the draft ordinance amending Article 40, Planned Development No. 1144 of the City Code by revising the rear lot setback requirement for Zone 2. Roll call vote: Ayes – 5 – Nays – 0. B. §155.320 (Cannabis Businesses, Hemp Businesses, and Temporary Cannabis Events) Text Amendment Chair Kurtz opened the public hearing. Associate Planner Stroeing provided a brief presentation. With no further comments, Chair Kurtz closed the public hearing. MOTION: Commissioner Hlas moved, seconded by Commissioner Schindler, to recommend approval of the draft ordinance amending §155.320 (Cannabis Businesses, Hemp Businesses, and Temporary Cannabis Events) to address the procedure of measuring setback buffers for cannabis businesses. Roll call vote: Ayes – 5 – Nays – 0. C. §155.397 (Variances) Text Amendment Chair Kurtz opened the public hearing. Associate Planner Stroeing provided a brief presentation. With no further comments, Chair Kurtz closed the public hearing. MOTION: Commissioner Scanlan moved, seconded by Commissioner Hlas, to recommend approval of the draft ordinance amending §155.397 (Variances) requiring a public hearing for variance requests. Roll call vote: Ayes – 5 – Nays – 0. 5. LAND USE A. Resolution Declaring City-Owned Lands (Central Village West site) as Surplus and In Conformance with 2040 Comprehensive Plan MOTION: Commissioner Schindler moved, seconded by Commissioner Scanlan, to adjourn the meeting at 7:19 p.m. Roll call vote: Ayes – 5 – Nays – 0. CITY OF APPLE VALLEY Dakota County, Minnesota Planning Commission Minutes August 6, 2025 Page 3 of 3 6. OTHER BUSINESS A. Review of Upcoming Schedule and Other Updates The next Planning Commission meeting is scheduled for Wednesday, August 20, 2025, 7:00 p.m. The next City Council meeting is Thursday, August 14, 2025 at 7:00 p.m. 7. ADJOURNMENT Chair Kurtz asked for a motion to adjourn. MOTION: Commissioner Schindler moved, seconded by Commissioner Scanlan, to adjourn the meeting at 7:19 p.m. Roll call vote: Ayes – 5 – Nays – 0. Respectfully submitted, ______________________________________ Breanna Vincent, Planning Department Assistant Approved by the Apple Valley Planning Commission on 09/03/2025 . Jodi Kurtz, Chair ITEM: 5.A. MEETING DATE: September 3, 2025 SECTION: Land Use / Action Items Description: Valley Station Apartments - PC25-13BGZ Consider Planned Development Amendments & Site Plan/Building Permit Authorization to allow construction of 144-unit apartment building. LOCATION: 15584 Gaslight Drive APPLICANT: Real Estate Equities Staff Contact: Terri Dill, City Planner Department / Division: Community Development Action Requested: Recommend approval of Zoning Text Amendments and Site Plan/Building Permit Authorization for Valley Station Apartments. Summary: The applicant, Real Estate Equities (REE), requests amendments to Appendix F, Article 18, Planned Development No. 507, and Site Plan/Building Permit Authorization to allow construction of Valley Station Apartments, a 144-unit affordable workforce housing apartment development on Lot 1, Block 2, Carroll Center 4th Addition. The 3.10-acre parcel is located at the southeast corner of 155th Street West and Gaslight Drive. Surrounding land uses include the Minnesota Valley Transit Authority transit station to the north, the Floor and Décor building and parking lot to the west, Orchard Square/Cortland Apartments to the south, and Chasewood Family Townhomes to the east. The site, often referred to as the Gaslight Site, was initially acquired by the Apple Valley Economic Development Authority (EDA) in 1997 and subsequently leased to the Minnesota Valley Transit Authority (MVTA) for use as a park and ride site. Due to improvements to the nearby transit station in 2020, which increased the capacity to 1,200 parking stalls and overall shifts in transit usage, MVTA and the Metropolitan Council agreed to release their interests in the site. In 2024, the EDA issued a request for proposal (RFP) to redevelop the subject site. Three development proposals were considered, and REE’s workforce housing apartment development was chosen. A purchase agreement was subsequently executed for the proposed workforce housing apartment development. The Planning Commission reviewed this item at its meeting on July 16, 2025. After receiving initial feedback, the developer has revised the plans based on comments received at the meeting. The number of apartment units has been reduced from 148 to 144 units; the building height has been lowered to four-stories at the northeast portion of the building to lessen the impact on the adjacent multi-family units; an indoor playground has been added to provide a year-round play area for children; and additional parking has been added to the development. Background: The subject property is currently guided SIHD – Suburban Intensive High Density, which allows densities of 24 to 48 units per acre on sites exclusively for residential uses located adjacent to the transit station. With a reduction in apartment units, the proposed development now has a net density of 46.45 units per acre, which aligns with the 2040 Comprehensive Plan. The parcel is currently zoned PD-507/Zone 2 (Planned Development). Multiple family is a permitted use within this district; however, the following planned development district amendments are being requested to PD 507 Subzone 2: 1. Reduce the setback required along a neighborhood collector street from 40 feet to 25 feet. 2. Increase the maximum units per acre from 16 to 48. 3. Reduce the minimum square footage of land required per unit from 2,760 square feet to 916 square feet. 4. Allow coverage to increase from 20% to 30% of the lot. 5. Increase the maximum number of stories from three stories to five stories and the maximum height from 45 feet to 60 feet. 6. Eliminate the minimum one to three roof pitch requirement to allow for a flat roof. Site Plan The proposed site plan includes a five-story building containing 254,356 square feet. The building is situated with the main entrance facing east and will have a 30-foot setback from Gaslight Drive, a 15- foot setback on the south property line, and a 25-foot setback along 155th Street. The nearest adjacent dwelling unit is located approximately 95 feet from the proposed apartment building. The site will gain access from 155th Street and Gaslight Drive, with the west driveway extending under the building, with three floors located above. The project will provide community amenities for its residents, including a clubroom, outdoor patio/grilling area, fitness center, bike storage, electric car chargers, dog run, and an indoor and outdoor playground. The proposed units range from one to three-bedroom apartments, with the total of each type shown below: UNIT TYPE NUMBER OF UNITS ANTICIPATED RENTS 1-Bedroom 35 $1,406 2-Bedroom 72 $1,684 3-Bedroom 37 $1,941 The apartments will serve households with incomes at 60% area median income (AMI), which is calculated annually by the U.S. Department of Housing and Urban Development. Below are the maximum income restrictions: HOUSEHOLD SIZE INCOME RESTRICTIONS 1-Person Household $55,620 2-Person Household $63,600 3-Person Household $71,520 4-Person Household $79,440 On-Site Parking and Traffic Review Revisions to the underground parking and surface lot enabled an increase in the total number of parking spaces from 240 to 258. Underground parking increased from 162 to 178 spaces, and surface parking increased from 77 to 80. The site now provides a parking ratio of 1.79 spaces per unit. There will be no additional charges for resident parking in this proposed development. Monthly fees for parking on multi-family projects can lead to parking issues when residents avoid the extra costs and find alternative parking, which often includes on-street or utilizing private retail sites. Transportation Collaborative and Consultants LLC has completed a traffic and parking analysis. The main objective of the study was to quantify the existing traffic and parking conditions and evaluate potential impacts. Staff requested a detailed parking assessment to determine if the proposed parking spaces were sufficient. Using the Institute of Transportation Engineers (ITE) Parking Generation Manual, 6th Edition, the 85th percentile peak parking demand at peak average parking demand is expected to range from 202 to 235 spaces, with the average demand range from 144 to 160 spaces. In summary, the analysis of the parking supply is expected to accommodate the peak parking demand for the proposed development, and no parking impacts are expected on adjacent sites or roadways. Please note that two surface spaces were added after the analysis was completed. The study also evaluated traffic volumes, transportation characteristics, crash history, and intersection capacity. A trip generation estimate was created using the ITE Trip Generation Manual, 11th Edition. The intersection capacity analysis indicated that the intersections and approaches are expected to continue to operate at Level of Service (LOS) B or better during peak hours with no significant operational issues created from the proposed development. An analysis of the 155th Street and Gaslight Drive intersection was completed, indicating that existing and future traffic volumes do not meet the criteria for a traffic signal or an all-way stop condition. Landscape Plan A variety of landscape plantings are shown on the landscape plan, including trees along the west and south property lines, foundation plantings, and parking lot islands. A six-foot vinyl fence is proposed along the east property line with plantings to provide screening from adjacent rental townhomes. Black ornamental fencing is also used within the interior site to enclose the tot lot, dog run, and outdoor patio area, and to provide a safety barrier along the retaining walls. A final landscape plan must be submitted for City staff review and approval before a building permit can be issued. The applicant will need to meet the landscape requirements outlined in the Zoning Code, which requires landscape improvements to be equal to 2.5% of the estimated building construction costs. Pedestrian Access Currently, sidewalk runs along the south side of 155th Street and the east side of Gaslight Drive. The site plan shows sidewalk connections at building exits on the north and west sides of the building. An internal sidewalk runs in front of the building and extends north along the parking lot to a building exit; staff recommend that this sidewalk continue north to connect to the sidewalk along 155th Street. The City is reviewing potential pedestrian crossing improvements that the developer will be required to provide to ensure a safe pedestrian crossing on 155th Street at Gaslight Drive, facilitating access to the MVTA Station. Additionally, the developer will be required to make lighting improvements along 155th Street and Gaslight Drive to ensure safe pedestrian walkways are available during evening hours. Architecture The proposed building incorporates architectural features that are compatible with the surrounding area, providing visual relief through both horizontal and vertical elements. Exterior building materials include stone veneer/cultured stone, with secondary materials being cement fiber (James Hardie) siding and decorative rockface concrete masonry unit (CMU). The building colors feature a natural earth-tone palette of cream and white hues on the upper portion of the building to minimize height, and this color palette is complemented by contrasting darker bronze/gray tones. Final plans will need to include parapet walls to completely screen all rooftop units from public view. Public Hearing Comments The public hearing for this item was held on July 16, 2025. The Planning Commission and residents raised the following comments and questions, and staff responses are included below: 1. How can you mitigate the change in the character of the area with a five-story building? The developer has revised the architectural plans, reducing the building height from five stories to four stories at the northeast corner of the building to provide a smoother transition to the two-story townhomes to the east. The change reduces the number of units from 148 to 144 and the density from 47.74 to 46.45 units per acre. 2. Is it possible to recess one of the stories? Yes, however, the developer indicated that in discussions with the architect, they did not feel this would provide a significant enough impact to reduce the appearance of the building height, so they did not pursue this option and opted to reduce the building to four stories at the northeast corner. 3. Who will maintain the existing sidewalk and trees/shrubs along the east property line adjacent to Chasewood Family Townhomes? REE will maintain the infrastructure and landscaping located on its property. Maintenance of the existing sidewalk and plantings located along the east property line within the Chasewood Family Townhomes development is the responsibility of Dakota County CDA. With the discontinuation of the park and ride site, the landscaping along the common lot line has become overgrown. The proposed landscape plan will include new plantings and a six- foot privacy fence for screening. 4. What is the typical number of residents per unit? REE has indicated that they tend to see 1.2 to 1.3 residents per bedroom. They also stated that it is common for a one-bedroom unit to have two occupants, which drives the ratio up and would equate approximately 2.4 to 2.6 residents per unit. 5. Will there be enough guest parking? The traffic and parking review includes a detailed analysis of the on-site parking supply by a traffic engineer using ITE standards. The study's results indicate that the proposed parking supply can accommodate the proposed use. 6. What are the typical parking ratios per unit in the Twin Cities for two and three- bedroom units? The traffic and parking analysis provides parking ratios for multi-family apartment developments owned and operated by REE, with the bedroom units included in the comparisons. The study includes additional parking ratios for comparison purposes on the back page. 7. Will residents park in the cul-de-sac to the southeast? Staff do not believe parking will occur in the cul-de-sac because the proposed fence, landscaping, and grade change do not make it an easy walk to the apartments for residents. 8. Can fire trucks maneuver within the site? Yes, the developer has provided the required turning movement exhibits, which demonstrate that it will meet the turning radius. 9. Will a traffic signal be required? No, the preliminary traffic signal and all-way stop warrant analysis indicated that the intersection is not even close to meeting the criteria. 10. What are the estimated traffic volumes with the apartments and vehicles using the adjacent transit facilities? The estimated traffic volumes have been included in the traffic and parking review analysis. 11. How many residents will only use transit and will not have a vehicle? This data is hard to quantify, but the developer stated that about 20% of adult residents living at REE properties do not have a car, and it was noted that the other REE sites are not located near a transit station, making it more likely that residents will not need to rely on a personal vehicle. 12. What is the height of The Legends apartments compared to the proposed apartment building? Valley Station Apartments is 57 feet tall, and the Legends apartment building ranges in height from 52 to almost 72 feet, due to the grade and pitched roof. The developer has provided an exhibit that provides a side-by-side comparison. 13. Request for a formal lighting plan with emphasis along the east property line. Will light affect adjacent housing – will light shine in adjacent homes? A photometric plan was submitted showing estimated light levels ranging from 0.01 to 0.03 footcandles at the property line, which will not create a disturbance. Site and building lighting on the site must all consist of downcast, cut-off light fixtures or wall packers with deflector shields. 14. How does the proposed density compare to the developments to the east and south? Chasewood Rental Townhomes net density is 10.9 units per acre, and Orchard Square/Cortland Apartments has a net density of 22.8 units per acre. 15. How does the green space and playground size compare to the developments to the east? Is there a way to measure what size playground or dog run is needed for the size of the proposed apartment project? Dakota County’s CDA owns and manages the adjacent multi-family developments, and Chasewood Rental Townhomes includes a 6,480 square foot outdoor play/gathering area. The Orchard Square/Cortland senior apartments include a walkway and open area along the north portion of the property. Unfortunately, there are no standards used for sizing playgrounds or dog runs in private apartment projects, but the developer has provided comparisons. 16. What is the impact on the utilities – electric, water, and sewer? The existing electric, water, and sewer utilities have been sized appropriately, and there would be no negative impacts. The sanitary sewer main currently bisects the site; it has been further studied, and it is proposed to be reconstructed by the developer to ensure its long- term functionality. 17. Height will block views of adjacent homes – will apartment residents be able to look into the Cedar Point townhome windows? The height of the proposed apartments will exceed that of the Cedar Point townhomes, which are two-story structures. Although they are located more than 200 feet away, it may be possible to look into a window if there are no window coverings in place. 18. Could a mistake have been made for this site in the 2040 Comprehensive Plan? The 2040 Comprehensive Plan designated this area as SIHD, and the Land Use Chapter (pages 4-24 to 4-25) includes details that SIHD was located on sites adjacent to transit services. The section also provides use type examples and lists multi-story apartments, condominiums, and cooperative complexes. The section also notes that the SIHD designation did not increase the existing densities of the parcels and pointed out that the City had already approved the densities. The subject site was designated for mixed-use in the 2030 Comprehensive Plan, which includes high-density housing. 19. Will the greenway area on the Cortland apartments be affected? Who owns and maintains this area? No, this area will not be affected. It is owned and maintained by Dakota County CDA. 20. Will there be a buffer to the south and east? Yes, landscape plantings will provide a buffer. 21. Will there be a sidewalk connection to the east or south? No, there will not be sidewalks to the east or south. 22. Concerns with crime and safety Input was sought from Chief Francis regarding calls for service at the existing affordable housing developments. Details on calls for service for a one-year period at the three existing affordable townhome developments are provided in Exhibit B. Chief Francis stated that, in general, as population density increases, it creates additional demand for public safety (Police, Fire, and EMS). Valley Station Apartments would be the first affordable workforce apartment project in our City, and generally, apartment developments generate additional calls due to shared walls and the closeness of residents. Chief Francis noted that Apple Valley is the most densely populated city in Dakota County, after West St. Paul and South St. Paul, and it stands to reason that higher-density housing will result in an increase in city services related to public safety, and added, not that it’s a bad thing, it’s just the reality. Budget Impact: Park dedication will be required as part of the development agreement and is determined based on the parkland demand created by the use. The amount of parkland required for each resident is based on the need to achieve the park services standard, which the City has set through its historic parkland development. The City standard is 0.00955 acres of parkland area needed for each resident. Where cash-in-lieu of land is taken, the value of the land shall be based on the benchmark values of raw land that are set by the City Council based on periodic review of market conditions. Present benchmark values for 144 multi-family units, as per the 2025 Fee Schedule, equate to a park dedication of $574,834. Attachments: 1. Site Location 2. Zoning Map 3. Ordinance 4. Resolution - Issuance Builidng Permit 5. Exhibit A Playground and Dog Run Comparisons 6. Exhibit B Calls for Public Service 7. Valley Station Apartments - Engineering Review 8. Valley Station Apartments - Inspections Review 9. Height Comparison to Legends 10. Valley Station Apartments Civil Plans 11. Valley Station Apartments Architectural 12. Valley Station Apartments Photometric Plan 13. Valley Station Apartments Traffic and Parking Analysis CITY OF APPLE VALLEY ORDINANCE NO.___ AN ORDINANCE OF THE CITY OF APPLE VALLEY, AMENDING CHAPTER 155 APPENDIX F, ARTICLE 18, OF THE CITY CODE REGULATING PLANNED DEVELOPMENT DESIGNATION NO. 507 The City Council of Apple Valley ordains: Section 1. Chapter 155, Appendix F, Article 18 of the Apple Valley City Code is amended by revising Section 18-5(A)(1), in part to read as follows: § A18-5 MINIMUM AREA STANDARDS AND REQUIREMENTS (A) The following requirements and minimum area standards shall be met. No improvements shall be placed on such lands unless the lands to be so used or improved shall meet the following minimum area and dimensional requirements. Densities are predicated upon the availability of public water, storm sewer, and sanitary sewer service; without the service, densities shall be limited to one dwelling unit or structure per ten acres. The following table shall be used to compute the minimum lot area exclusive of street rights-of-way, in square feet, and such computation shall be subject to the following; ponding area or similar unbuildable areas shall not comprise more than 10% of the total site area. (1)Table of minimum area standards and requirements. The dimensions shall be measured in feet unless otherwise specified. MINIMUM REQUIREMENTS FOR DESIGNATION NO. 507 Requirements Zone 2 Minimum Lot Areas for Multi-Family Dwelling Unit Density Minimum square footage of land per unit, (plus bonus)916 Maximum units per acre 48 Minimum Lot Areas for Multi-Family Dwelling Unit Density Along community or neighborhood collector streets 25 Maximum Building Coverage Coverage of lot (percentage)35% Maximum Building Height Maximum Number of Stories 5 Maximum Height 60 Section 2. Summary approved. The City Council hereby determines that the text of the summary marked "Official Summary of Ordinance No. _____” a copy of which is attached hereto clearly informs the public of the intent and effect of the ordinance. The City Council further determines that publication of the title and such summary will clearly inform the public of the intent and effect of the ordinance. 2 Section 3. Filing. The City Clerk shall file a copy of this ordinance in her office, which copy shall be available for inspection by any person during regular office hours. Section 4. Effective Date. This ordinance shall take effect upon its passage and publication of its title and official summary. PASSED by the City Council this _____ day of August, 2025. Clint Hooppaw, Mayor ATTEST: _______________________________ Christina M. Scipioni, City Clerk 3 CITY OF APPLE VALLEY ORDINANCE NO. _____ AN ORDINANCE OF THE CITY OF APPLE VALLEY, AMENDING CHAPTER 155 APPENDIX F, ARTICLE 18, OF THE CITY CODE REGULATING PLANNED DEVELOPMENT DESIGNATION NO. 507 The following is the official summary of Ordinance No. ____ passed by the City Council of Apple Valley on _________________, 2025: This Ordinance amends Chapter 155-Appendix F, Article 18 (Planned Development No. 507) by amending Section 18-5(A)(1) to allow the minimum square footage of land per unit to be 916 sq. ft.; allow maximum 5 stories, allow maximum height of 60 feet; allow maximum 48 units per acre; allow setback of 25 feet along neighborhood collector streets, allow maximum building coverage of 35%, and amending Section 18-5(A)(2) eliminating the requirement that multiple-residential buildings shall have a one to three roof pitch. A printed copy of the ordinance is available for inspection by any person during regular office hours in the office of the City Clerk at the Apple Valley Municipal Center, 7100 147th Street W., Apple Valley, Minnesota 55124. CITY OF APPLE VALLEY RESOLUTION NO. 2025-___ A RESOLUTION AUTHORIZING THE ISSUANCE OF A BUILDING PERMIT FOR VALLEY STATION APARTMENTS AND ATTACHING CONDITIONS THERETO WHEREAS, pursuant to Minnesota Statutes 462.357 the City of Apple Valley has adopted, as Title XV of the City Code of Ordinances, zoning regulations to control land uses throughout the City; and WHEREAS, said regulations provide that issuance of a building permit for commercial, industrial, institutional and multiple residential uses require the specific review and approval of development plans by the Apple Valley Planning Commission and City Council; and WHEREAS, approval of a building permit authorization of a proposed 144-unit workforce apartment building, on property legally described as Lot 1, Block 2, Carroll Center 4th Addition, Dakota County, Minnesota; and WHEREAS, the Apple Valley Planning Commission reviewed the development plans and recommended approval at its regular meeting on DATE. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Apple Valley, Dakota County, Minnesota, that the issuance of a building permit for Valley Station Apartments to be located within Lot 1, Block 2 Carroll Center 4th Addition, subject to all applicable City Codes and standards, and the following conditions: 1. If the building permit is not paid for and issued within one (1) year of the date of approval, the approval shall lapse. 2. Issuance of any building permits shall be subject to the approval and recording of the storm water maintenance agreement and development agreement, and associated documents. 3. Construction shall occur in conformance with the site plan dated DATE, including parking lot paving and a non-surmountable concrete curb and gutter. 4. Construction shall occur in conformance with the landscape plans dated DATE (including sodded/seeded public boulevard area up to each street curbline); subject to submission of a detailed landscape planting price list for verification of the City’s landscaping requirement at the time of building permit application. 5. Construction shall occur in conformance with the elevation plans dated DATE. 6. Subject to all conditions noted in the City Engineer’s memo dated July 10, 2025, on file with the City. 2 7. Subject to all conditions noted in the Building Official’s memo dated June 24, 2025, on file with the City. 8. All necessary mechanical protrusions visible to the exterior shall be screened or handled in accordance with Section 155.346 (3) (a) (b) of the city code. If the proposed roofline or parapet wall(s) is found to not be a sufficient screen, other code compliant screening shall be installed. 9. Screening any outdoor utility meters and boxes shall be achieved through landscaping, fence, decorative screen or a combination thereof, and approved by the City. 10. Pedestrian crossing improvements shall be installed on 155th Street and Gaslight Drive to provide a safe pedestrian crossing to access the MVTA Station. 11. Street lighting shall be installed along 155th and Gaslight Drive to ensure safe pedestrian walkways are available during non-daylight hours. 12. A bike rack shall be installed close to the primary structure which does not impede pedestrian flow along any proposed or future sidewalk. 13. Site grading shall occur in conformance with a Natural Resources Management Plan (NRMP) which shall include final grading plan to be submitted for review and approval by the City Engineer; subject to the applicant submitting a copy of the General Storm Water Permit approval from the Minnesota Pollution Control Agency pursuant to Minnesota Rules 7100.1000 - 7100.1100 regarding the State NPDES Permit prior to commencement of grading activity. 14. Infiltration areas shall be constructed in conformance with the City standards and the property owner shall execute a maintenance agreement or other suitable agreement to be filed with the deed that ensures the perpetual maintenance of infiltration areas. 15. Site and building lighting shall consist of downcast, shoebox lighting fixtures or wall packs with deflector shields which confines light to the property and shall be installed in conformance with Section 155.353 of the city code. 16. Approval of a signage plan is not included with this site plan and building permit authorization. A separate application and signage plan in conformance with the sign regulations must be submitted for review and approval to the City prior to the erection of any signs. 17. Construction and earthmoving activities shall be limited to the hours of 7:00 a.m. to 7:00 p.m. Monday through Friday. Weekend construction hours shall be limited to Saturdays during the hours of 8:00 a.m. to 5:00 p.m. 3 18. Prior to issuance of a building permit, a construction staging and construction personnel parking plan shall be submitted and approved by the City. 19. Earthmoving activities shall not occur when wind velocity exceeds thirty (30) miles per hour. Watering to control dust shall occur as needed and whenever directed by the Apple Valley Building Official or Zoning Administrator. 20. Issuance of a Building Permit and a final certificate of occupancy is contingent upon the project being constructed in conformance with all the preceding conditions as well as all applicable performance standards of the current zoning regulations. In the event that a certificate of occupancy is requested prior to completion of all required site improvements, a suitable financial guarantee in the amount of 125% of the estimated cost of the unfinished improvements shall be required along with an agreement authorizing the City or its agents to enter the premises and complete the required improvements if they are not completed by a reasonably stipulated deadline, with the cost of such City completion to be charged against the financial guarantee. 21. The ongoing use and occupancy of the premises is predicated on the ongoing maintenance of the apartment building and all required site improvements as listed in the preceding. No alteration, removal, or change to the preceding building plans or required site improvements shall occur without the express authorization of the City. Site improvements which have deteriorated due to age or wear shall be repaired or replaced in a timely fashion. BE IT FURTHER RESOLVED that such issuance is subject to a finding of compliance of the construction plans with the Minnesota State Building Code, as determined by the Apple Valley Building Official, and with the Minnesota State Uniform Fire Code, as determined by the Apple Valley Fire Marshal. ADOPTED this ___th day of August, 2025. __________________________________ Clint Hooppaw, Mayor ATTEST: ___________________________________ Christina M. Scipioni, City Clerk Playground Area Units SF/Unit Valley Station Apartments 1,364 144 9.47 Landing at Amber Fields 860 160 5.38 Arbor Court 1,932 114 16.95 Spring House 861 168 5.13 Aster House 477 204 2.34 PLAY AREA ANALYSIS EXHIBIT A Dog Run Area Units SF/Unit Valley Station Apartments 1,189 144 8.26 Landing at Amber Fields 1,082 160 6.76 Arbor Court 1,440 114 12.63 Spring House 1,488 168 8.86 Aster House 3,035 204 14.88 Dog Run Analysis Total CFS 911 Hangup 8 Accident /Injuries 4 Accident/No injury 4 Motorist Assist 1 Paper Service/Civil 3 Premise Check 2 Road and Driving Comp 2 Suspicious Activity 2 Threats/Stalking 2 Traffic Stop 13 Welfare Check 6 Grand Total 47 Top 5 CFS Traffic Stop 13 911 Hangup 8 Welfare Check 6 Accident/Injuries 4 Accident/No injury 4 Chasewood Townhomes Calls for Service: 7/28/24-7/28/25 EXHIBIT B27 Units Quarry View Townhomes Calls for Service: 7/28/24rry View Townhomes Calls for Service:Quarry View Townhomes Calls for Service: 7/28/arry View Townhomes Calls for Service: 7/28/24Quarry View Townhomes Calls for Service: 7/28/24--7/28/257/28/25 Total CFS 911 Hangup 16 Admin Background/Permits 1 Animal Calls 3 Assault RPT 1 Assist Other Juris 1 Civil Assist 4 Crisis Mental Health 3 Disturbance/Disorderly 8 Harassment 3 Juvenile Complaint 1 Medical 4 Missing Person/Runaway 2 Premise Check 2 Suspicious Activity 3 Theft RPT 2 Grand Total 54 Top 5 CFS 911 Hangup 16 Disturbance/Disorderly 8 Civil Assist 4 Medical 4 Suspicious Activity 3 Animal Calls 3 Crisis Mental Health 3 Harassment 3 45 Units GlenbrookGlenbrook TownhomesTownhomes Calls for Service: 7/28/24Calls for Service: 7/28/24ervice: 7/28/24--7/28/257/28/25 Total CFS 911 Hangup 15 Animal Calls 1 Assault In Progress 6 Assault RPT 2 Civil Assist 5 Crisis Mental Health 6 Disturbance/Disorderly 9 Domestic/Disputes in Progress 3 Fire Alarm 3 Fire Related Call 2 Follow up 5 Juvenile Complaint 4 Medical/Priority 15 Paper Service/Civil 10 Premise Check 4 Suspicious Activity 6 Theft RPT 1 Tow Repo/Private 4 Utility Callout 2 Vandalism/Property Damage 3 Welfare Check 3 Grand Total 109 Top 5 CFS 911 Hangup 15 Medical/Priority 15 Paper Service/Civil 10 Disturbance/Disorderly 9 Suspicious Activity 6 Crisis Mental Health 6 Assault In Progress 6 39 Units City of Apple Valley Public Works | Engineering MEMORANDUM DATE: August 29, 2025 TO: Terri Dill, City Planner FROM: Evan Acosta, Assistant City Engineer SUBJECT: Valley Station Apartments Site Plan Review per plans dated 08/7/2025 Terri, The following are comments regarding the Valley Station Apartments preliminary site plans dated August 7, 2025 (and updated 8/28/25). Please include these comments as conditions of approval. General 1. All work and infrastructure within public easements or right of way shall be to City standards. 2. Provide a narrative of how the buildings will be constructed and any impacts. The narrative shall include the following: a. Shoring (if applicable) b. Material Storage. c. Haul routes to and from the site. d. Phasing 3. No construction work shall begin prior to a preconstruction meeting conference with a Public works and a Building Inspections representative. 4. Provide a copy of the approval letter from the Department of Labor and Industry (DOLI) prior to construction. 5. Public Work Department (952-953-2400) shall be notified a minimum of 48 hours for any required water main shut downs and/or connections. 6. A stormwater maintenance agreement will be required for the pretreatment structure(s) and underground chamber on the property. 7. Plans should include reference to all used City of Apple Valley standard detail plates. All Standard detail plates should be shown in the details section of the plans. 8. No trees will be permitted in public easements except where identified as replacement or otherwise approved by Public Works. Permits 9. Provide a copy of the executed Minnesota Department of Health, Minnesota Pollution Control Agency, Met Council, Department of Labor and any other required permits prior to construction. 10. Department of Labor and Industry (DOLI) shall review private utilities. 11. A right of way permit will be required for all work within public easements or right of way. 12. A Natural Resource Management Permit (NRMP) will be required prior to any land disturbing activity commences. 13. Since the site will be disturbing more than 1 acre and creating more than 1 acre of new impervious. The applicant will be subject to the requirements of the State NPDES Construction Storm water Permit. The applicant must provide proof of permit. City of Apple Valley Public Works | Engineering MEMORANDUM Traffic 14. The applicant has provided a traffic memorandum (included in Planner’s Staff Report) that was reviewed by engineering. Neither traffic signal warrants nor “all way stop” warrants are being met for Gaslight Dr/155th St W. 15. The City is reviewing the Dakota County Crossing Matrix and the proposed site plan for potential crossing improvements on 155th St W at Gaslight Drive to access the MVTA Station. • This may include lighting along Gaslight Drive or 155th Street West. Site 16. Final Site Plan subject to City Engineer Approval. 17. Include Auto turn drawings for both: • Service and emergency vehicles entering and leaving the site. •Ingress/Egress of vehicles into the parking garages (at grade and below grade) 18. Provide a sight line exhibit with dimensions. 19. Pavement section for public roadways shall match existing roadways and be shown on the plans. 20. Provide detail on snow storage. 21. Show the location of manholes and gate valves and hydrants on the site plan. 22. Show existing easements on the site/grading and utlity plans. Permanent structures are not allowed in drainage and utility easements or private storm water facilities. 23. Signage Plan and details should be included on site plan (i.e. pedestrian crossing signage, ADA, directional signs, no parking, buffer/storm water signs, no snow storage in storm water basins, etc…) for review 24. Driveway Apron shall be per City of Apple Valley standard detail plate STR-5. 25. All retaining walls over 48” from bottom of footing to the top of wall shall be designed and certified by a structural engineer and submitted to building inspections for final approval. Retaining walls over 4’ will require a fence above the wall. Provide additional details and/or specifications for retaining wall block. Retaining walls shall be privately owned and maintained. Retaining walls are not allowed in drainage and utility easements without an approved encroachment agreement. 26. Show locations of proposed lighting fixtures for parking lots and site. 27. Site plan should show site line triangles at access entrances as well as on the landscape plan 28. Drainage and utility easements should be shown on Plans. Grading & Drainage Plan 29. Grading limits are shown crossing the property lines to the north and south. There is no concern on the shared grading between the proposed Seven Brew and McDonald’s lot. City of Apple Valley Public Works | Engineering MEMORANDUM However, a letter from the property owner to the north (Health Partners Clinic) is required to grade on their property. 30. Final Storm Water Pollution Prevention Plan (SWPPP) shall be included with plans and shall be reviewed and approved by City Engineer. 31. Final Grading Plans shall be reviewed and approved by City Engineer. 32. Provide the overall site composite Curve Number (CN) along with the impervious % on the area tabulation. 33. Label the EOF’s on the grading plan. 34. Provide elevations for top & bottom of all retaining walls. 35. Maximum driveway grades are 10% and should incorporate a landing taper for driver sight line. Storm Sewer 36. Final locations and sizes of Storm Sewer shall be reviewed with the final construction plans and approved by City Engineer. 37. Provide a pre-sedimentation cell or pretreatment device/s, such as a SAFL Baffle or approved equal and sump prior to discharging into the public storm sewer in an additional separate MH. Sump structures as shown in City “Catch Basin Manhole with Sump” detail STO-5S. Any sumps shall be privately maintained and routinely cleaned as the accumulated sediment will be from the private parking lots and roadways. 38. Storm sewer within right of way and public drainage and utility easement for purposes of connection to public infrastructure shall be reinforced concrete pipe and meet all City standards. 39. Submit a Storm water Management Checklist. The checklist can be found on the City’s website at https://www.cityofapplevalley.org/DocumentCenter/View/16258/Project- Submittal-Checklist_Fillable Sanitary Sewer and Water main 40. Final locations and sizes of Water main shall be reviewed with the final construction plans and approved by City Engineer. 41. The sanitary sewer main on the property will be reconstructed with City created plans and specifications per the executed Design Agreement. 42. All water mains located within right of way and public easements for purposes of connection to public infrastructure shall be ductile iron pipe and meet all City standards. 43. Provide gate valves on all water lines going into the buildings including fire suppression lines in accordance with City Detail plate SER-6. 44. Remove unused sanitary and water services to the main and indicate on plans. 45. All watermain shall be a min depth of 8.0’. 46. Identify Irrigation service location(s) if applicable per SER-4. 47. Provide additional drawing showing required hydrant coverage for site. City of Apple Valley Public Works | Engineering MEMORANDUM Landscape and Natural Resources 48. According to City Code, tree planting must follow 15-10-5 diversity rule, meaning tree landscape schedule must not exceed 15% of any plant family, 10% of any plant genus, and 5% of any species. Current plant schedule does not meet the diversity rule. Please diversify plant schedule to meet requirements. 49. Current landscaping plan does not include maples, but planting of maple species is highly discouraged due to severe overplanting. Please consider alternative species when re- designing plant schedule. 50. Austrian Pine is no longer typically recommended due to its susceptibility to a variety of disease and insect issues. If using, please use minimally and diversify with other conifer species. City of Apple Valley Public Works | Building Inspections MEMORANDUM DATE: June 24, 2025 TO: Terri Dill, City Planner FROM: George Dorn, Chief Building Official SUBJECT: Terri, The following are comments regarding the Valley Station Apartment Project located at 15584 Gaslight Drive. •SAC determination is required from Met Council prior to permit issuance from the city. •Indicate Trash and recycling area calculations, Per MSBC 2020 1303.1500 Subpart 1, recycling space is required in accordance with Table 1-A on plans issued for permit. Please designate this recycling space at the time of permit submittal. •Submit plans to Minnesota Department of Labor, Plumbing Division for review of proposed plumbing, sanitary and storm design. •Retaining walls shall be designed by a Structural Engineer for walls over 4 feet. •Dog run shall not have any drains connected to the sanitary sewer. •Platting the property lines must be completed prior to permit issuance. •Architectural, Structural and Civil plans are required to be signed with the permit application. •The domestic and fire suppression water supply is required to be split outside the building with separate shut off valves. Contact our City Engineer for acceptable connections. •The allowable area and building heights will be determined once the code analysis has been completed. •The City of Apple Valley has adopted the 2020 MSBC 1306, subpart 3 Special Fire Protection systems. This section would require the buildings to have an automatic sprinkler system installed based on occupancy type and square footage. •Separate sign permits are required. Signed structural drawings will be required for review with the Building Permit application. •Per MSAC 502.4.4, the access aisles for the accessible areas shall be marked with a designation sign that says “no parking. Review areas under consideration for accessible parking areas. •Accessible parking required will be required per the Minnesota State Accessibility Code Table 1106.1 •Provide energy and lighting compliance calculations at the time of permit submittal. •Mechanical equipment and appliances on roofs or elevated structures shall be accessed in accordance with the 2020 Minnesota Mechanical Code 306.5. •Building Sewer slope is required to be in accordance with the 2020 Minnesota State Plumbing code.                           NDDVZLOVRQDUFKLWHFWV 9DOOH\6WDWLRQ$SDUWPHQWV&203$5,621 *DVOLJKW'U$SSOH9DOOH\01   1RUWK(OHYDWLRQB6' 9DOOH\6WDWLRQ$SSDUWPHQWV   1RUWK (DVW:LQJ(OHYDWLRQ /HJHQGVRI$SSOH9DOOH\$SSDUWPHQWV 12 20 16 18 22 22 22 22 26 15 14151819 1719 29 REMOVE TRASH ENCLOSURE REMOVE ELECTRICAL AND CONCRETE PAD REMOVE CURB/GUTTER-TYP REMOVE LIGHT POLE-TYP REMOVE SIGN-TYP REMOVE LIGHT POLE-TYP REMOVE CURB/GUTTER-TYP REMOVE CATCH BASIN-TYP REMOVE 18" RCP REMOVE MANHOLE-TYP MANHOLE TO BE REMOVED REMOVE 33" RCPREMOVE HC SIGNS-TYP REMOVE BOLLARD-TYP REMOVE PLANTER REMOVE PAVERS REMOVE BUILDING OVERHANG CONTRACTOR TO REMOVE BUILDING AND SERVICES AND TO MEET ALL APPLICABLE CITY AND STATE REQUIREMENTS REMOVE PAVERS REMOVE GAS LINE REMOVE BUILDING COLUMN REMOVE PAVERS REMOVE TREE GRATES REMOVE BENCHES REMOVE TREE GRATE REMOVE BIKE RACKS REMOVE TREE GRATE REMOVE BIKE RACKS REMOVE TREE-TYP. REMOVE 33" RCP REMOVE CONCRETE APRON REMOVE RAMP REMOVE PAVER DROP-OFF REMOVE FLAT CURB SAWCUT BITUMINOUS (FULL DEPTH) SAWCUT BITUMINOUS (FULL DEPTH) REMOVE RAMP SAWCUT BITUMINOUS (FULL DEPTH) REMOVE CONCRETE WALK REMOVE LIGHT POLE REMOVE LIGHT POLE MANHOLE TO BE REMOVED SANITARY SEWER TO BE REMOVED SANITARY SEWER TO BE REMOVED LOUCKS W: \ 2 0 2 4 \ 2 4 5 1 4 A \ c a d d D a t a \ C I V I L \ _ d w g S h e e t F i l e s \ C 1 - 1 D E M O L I T I O N P L A N Pl o t t e d : 0 8 / 2 8 / 2 0 2 5 1 1 : 2 5 A M 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD QUALIFICATION APPLE VALLEY GASLIGHT APARTMENTS APPLE VALLEY, MN REAL ESTATE EQUITIES 579 Selby Avenue St. Paul, MN 55102 06/11/25 CHECK SET 06/18/25 CITY SUBMITTAL 08/07/25 CITY RE-SUBMITTAL 08/28/25 CITY RE-SUBMITTAL C1-1 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-3 SWPPP NOTES C4-1 STORM SEWER PLAN C4-2 WATERMAIN & SANITARY PLAN C8-1 CIVIL DETAILS C8-2 CIVIL DETAILS L1-1 LANDSCAPE PLAN L1-2 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE Project Lead Drawn By Checked By Loucks Project No. 49933 24514A PJD DDL PJD 08/28/25 - N SCALE IN FEET 0 30 60 DEMOLITION PLAN C1-1 1. CONTRACTOR SHALL REMOVE AND/OR RELOCATE EXISTING PRIVATE UTILITIES AS NECESSARY. CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES & OWNER. 2. CLEAR AND GRUB AND REMOVE ALL TREES NOTED FOR REMOVAL, VEGETATION AND SITE DEBRIS WITHIN CONSTRUCTION LIMITS PRIOR TO GRADING. STRIP TOP SOIL AND STOCKPILE ON-SITE. ALL REMOVED MATERIAL SHALL BE HAULED FROM THE SITE DAILY. ALL CLEARING AND GRUBBING AND REMOVALS SHALL BE PERFORMED PER THE CONTRACT SPECIFICATIONS. EROSION CONTROL MEASURES SHALL BE IMMEDIATELY ESTABLISHED UPON REMOVAL. SEE THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) / GRADING & EROSION CONTROL PLAN. 3. CONTRACTOR SHALL PROTECT SURFACE AND SUBSURFACE FEATURES NOT NOTED FOR REMOVAL. CONTRACTOR TO NOTIFY ENGINEER WITH ANY CONFLICTS OR PLAN DISCREPANCIES. 4. CONTRACTOR TO SCHEDULE PRE-CONSTRUCTION MEETING(S) WITH UTILITY OWNER(S) TO DISCUSS DISCONNECTIONS AND/OR RELOCATIONS. 5. REFER TO TREE INVENTORY, TREE PRESERVATION, AND TREE REPLACEMENT PLAN FOR REMOVAL AND REPLACEMENT OF ON SITE TREES. 6. CONTRACTOR TO VERIFY LOCATION OF SEPTIC FIELD(S) & WELL(S) ON SITE. COORDINATE REMOVALS AND/OR ABANDONMENT WITH THE APPLICABLE GOVERNING AGENCIES. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING APPLICABLE PERMITS. WELLS ON THE PROPERTY SHALL BE SEALED BY A MINNESOTA DEPARTMENT OF HEALTH (MDH) LICENSED CONTRACTOR. 7. BITUMINOUS PAVEMENT REMOVALS ARE TO BE MADE TO A VERTICAL SAW CUT OR TO A NEAT MILLED EDGE. 8. CONCRETE PAVEMENT, SIDEWALK, CURB & GUTTER AND OTHER POURED CONCRETE ITEMS ARE TO BE REMOVED TO AN EXISTING EXPANSION OR CONTRACTION JOINT. SAW CUT AS NECESSARY FOR A NEAT EDGE OF REMOVAL. 9. ANY DAMAGE TO ITEMS NOT NOTED TO BE REMOVED SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REPAIRED OR REPLACED TO ORIGINAL CONDITION WITH NO ADDITIONAL COMPENSATION. 10. CONTRACTOR SHALL COORDINATE ALL WORK WITHIN THE PUBLIC RIGHT OF WAY WITH THE APPLICABLE GOVERNING AGENCIES. ALL WORK SHALL BE PERFORMED PER THE REQUIREMENTS OF THE APPLICABLE GOVERNING AGENCIES. 11. CONTRACTOR TO COORDINATE ALL WORK WITHIN THE ADJACENT PROPERTIES WITH THE OWNER AND ADJACENT PROPERTY OWNER. 12. CONTRACTOR TO COORDINATE DEMOLITION PHASING WITH ALL DISCIPLINES INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, & OWNER. 13. REFER TO THE GEOTECHNICAL REPORT PREPARED BY XXX, DATED XX, XXXX FOR INFORMATION INCLUDING BUT NOT LIMITED TO GROUNDWATER CONDITIONS AND RECOMMENDATIONS FOR EXCAVATION DEWATERING. 14. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR ANY REPAIRS TO THE IRRIGATION SYSTEM THAT IS AFFECTED DURING CONSTRUCTION. DEMOLITION NOTES WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. REMOVE EXISTING MANHOLES, POWER POLES, LIGHT POLES, BOLLARDS, PARKING METERS, SIGNS, ETC. REMOVE EXISTING CONCRETE PAVING, SIDEWALKS, ETC. REMOVE EXISTING TREES REMOVE EXISTING BITUMINOUS PAVING TREE PROTECTION FENCE DEMOLITION LEGEND PROPOSED BUILDING FFE-953.20 GFE-942.20 PROPOSED BUILDING FFE-953.20 GFE-942.20 25.0' 29.8' 25.0' 30.0' 31.2' 19.2' GA R A G E EN T R A N C E LE V E L - 1 CMU RETAINING WALL W/ PROTECTIVE ORNAMENTAL FENCE (2) - 5" HEIGHT CONCRETE STEPS HC SIGNAGE (SEE DETAIL) 10' CURB TAPER FLAT CURB (SEE DETAIL) 10' CURB TAPER GARAGE ENTRANCE LEVEL 1 GARAGE ENTRANCE LEVEL -1 FLAT CURB 23' CURB TAPER 10' CURB TAPER 5.0' 19.8' 24.0' 9.0' 9.0' 9.0' 9.0' 9.0' 9.0' 9.0' 20.0' 24.0' 24.0' 24.0' 24.0' 20.0'40.0' 24.0' 20.0' 24.0'24.0' 24.0' 24.0' 3-6" HEIGHT CONCRETE STEPS W/ METAL RAILING (SEE DETAIL) TOT LOT OUTDOOR PATIO 3' CURB TAPER 8' CURB TAPER 10' CURB TAPER 12.5' CURB TAPER 6.0' 38.3' 38.0' 42" HEIGHT ORNAMENTAL FENCE (SEE DETAIL) CONCRETE CURB EDGING (SEE DETAIL) CMU RETAINING WALL W/ PROTECTIVE ORNAMENTAL FENCE 6.0' NE W C O N C R E T E S I D E W A L K TRANSFORMER PAD PROPERTY LINE PROPERTY LINE B618 CURB/GUTTER TO MATCH EXISTING HC RAMP (SEE DETAIL) CONCRETE APRON (SEE DETAIL) HC RAMP (SEE DETAIL) 6.0' R7.0'R7.0' R3.0' R7.0' R3.0' R36.0' R18.0' R7.0' R3.0' R3.0' R7.0' R7.0' R3.0' R3.0'R3.0' R7.0' R7.0'R3.0' R3.0' R3.0' R3.0' HC SIGN-TYP (SEE DETAIL) 6.0' B612 CURB/GUTTER TYP 15.3' 236.3' 2' WIDE BITUMINOUS PATCH B618 CURB/GUTTER TO MATCH EXISTING 6.0' STOOPS - (SEE ARCH AND STRUCTURAL) 35 7 10 10 12 6 2-DUAL CHARGING STATIONS FOR 4 VEHICLES BIKE RACKS (SEE DETAIL) BIKE RACKS (SEE DETAIL) CONCRETE CURBING W/ FENCE AT DOG RUN FENCE ENCLOSED DOG RUN 30.0' 30' SIGHT TRIANGLE 30' SIGHT TRIANGLE 30' SIGHT TRIANGLE S1 S2 S1 S2 CMU RETAINING WALL (SEE DETAIL ON SHEET C8-1 LIGHTING POLE-TYP (SEE ELECTRICAL) LIGHTING POLE-TYP (SEE ELECTRICAL) LIGHT POLE-TYP (SEE ELECTRICAL) 3-6" HEIGHT STAGGERED CONCRETE STEPS (SEE DETAIL) 5.0' LOUCKS W: \ 2 0 2 4 \ 2 4 5 1 4 A \ c a d d D a t a \ C I V I L \ _ d w g S h e e t F i l e s \ C 2 - 1 S I T E P L A N Pl o t t e d : 0 8 / 2 8 / 2 0 2 5 1 1 : 2 6 A M 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD QUALIFICATION APPLE VALLEY GASLIGHT APARTMENTS APPLE VALLEY, MN REAL ESTATE EQUITIES 579 Selby Avenue St. Paul, MN 55102 06/11/25 CHECK SET 06/18/25 CITY SUBMITTAL 08/07/25 CITY RE-SUBMITTAL 08/28/25 CITY RE-SUBMITTAL C1-1 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-3 SWPPP NOTES C4-1 STORM SEWER PLAN C4-2 WATERMAIN & SANITARY PLAN C8-1 CIVIL DETAILS C8-2 CIVIL DETAILS L1-1 LANDSCAPE PLAN L1-2 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE Project Lead Drawn By Checked By Loucks Project No. 49933 24514A PJD DDL PJD 08/28/25 - SITE PLAN C2-1 1. ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND APPLICABLE GOVERNING AGENCY REQUIREMENTS. 2. ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND APPLICABLE GOVERNING AGENCY REQUIREMENTS. 3. ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4. ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. 5. BITUMINOUS IMPREGNATED FIBER BOARD TO BE PLACED AT FULL DEPTH OF CONCRETE ADJACENT TO EXISTING STRUCTURES AND BEHIND CURB ADJACENT TO DRIVEWAYS AND SIDEWALKS. 6. SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. 7. REFER TO THE GEOTECHNICAL REPORT PREPARED BY BRAUN FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO PAVEMENTS AND EXTERIOR SLABS. 8. THE SNOW STORAGE LOCATION WILL BE UP AGAINST THE EAST FENCE WHERE POSSIBLE. APARTMENT FACILITY WILL CONTRACT WITH WITH A MAINTENANCE BUSINESS FOR REMOVAL OF SNOW OFF SITE. SITE NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE SIGNAGE AND STRIPING AS SHOWN ON THIS PLAN. 2. CONTRACTOR SHALL PAINT ALL ACCESSIBLE STALLS, LOGOS AND CROSS HATCH LOADING AISLES WITH WHITE PAVEMENT MARKING PAINT, 4" IN WIDTH. 3. CONTRACTOR SHALL PAINT ANY/ALL DIRECTIONAL TRAFFIC ARROWS, AS SHOWN, IN WHITE PAINT. 4. ALL SIGNAGE SHALL INCLUDE POST, CONCRETE FOOTING AND STEEL CASING WHERE REQUIRED. 5. ALL SIGNAGE NOT PROTECTED BY CURB, LOCATED IN PARKING LOT OR OTHER PAVED AREAS TO BE PLACED IN STEEL CASING, FILLED WITH CONCRETE AND PAINTED YELLOW. REFER TO DETAIL(S). 6. ANY/ALL STOP SIGNS TO INCLUDE A 24" WIDE PAINTED STOP BAR IN WHITE PAINT, PLACED AT THE STOP SIGN LOCATION, A MINIMUM OF 4' FROM CROSSWALK IF APPLICABLE. ALL STOP BARS SHALL EXTEND FROM DIRECTIONAL TRANSITION BETWEEN LANES TO CURB. 7. ALL SIGNS TO BE PLACED 18" BEHIND BACK OF CURB UNLESS OTHERWISE NOTED. SIGNAGE AND STRIPING NOTES SITE AREA: 3.10 ± AC EXISTING IMPERVIOUS AREA: 2.72 ± AC (87.7%) PROPOSED IMPERVIOUS AREA: 2.06 ± AC (66.5%) SITE DATA PROPOSED SURFACE PARKING - STANDARD: 76 STALLS PROPOSED SURFACE PARKING - ACCESSIBLE: 4 STALLS TOTAL STALLS 80 STALLS REQUIRED ACCESSIBLE PARKING: 4 STALLS** **REQUIRED MINIMUM NUMBER OF ACCESSIBLE SPACES FOR 76 TO 100 STALLS PARKING DATA PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN    PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING  DIRECTION OF FLOW 1.0% 972.5 N SCALE IN FEET 0 30 60 WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. SIGNAGE LEGEND STOP SIGNS1 S2 NO PARKING-FIRE LANE 12" DIA. TYPICAL ADA PARKING SIGN / BOLLARD COMBO 12x18" STANDARD HANDICAP PARKING SIGN WITH SEPARATE 'VAN ACCESSIBLE' PANEL. WHITE LEGEND ON BLUE BACKGROUND. USE HARDWARE PER SIGN SUPPLIER'S RECOMMENDATIONS. HC SIGNAGE PER MINNESOTA RULES 1341.0502 12x6" STANDARD 'VAN ACCESSIBLE' PANEL. WHITE LEGEND ON BLUE BACKGROUND 2" DIA. 6' LONG MIN. GALVANIZED SCHEDULE 40 STEEL PIPE. EMBED IN CONCRETE FILLED BOLLARD 6" DIA. SCHEDULE 40 GALVENZIED STEEL PIPE 6' LONG MINIMUM HEAVY DUTY HDPE DOME TOP DECORATIVE SLEEVE BLUE IN COLOR. AVAILABLE FROM BOLLARDSNSLEEVES.COM OR EQUAL. COMPACTED OR UNDISTURBED SUBGRADE. NOTES: 1. BOLLARDS TO BE PLACED 12" BEHIND BACK OF CURB. 2. MAINTAIN PLUMB UNTIL CONCRETE IS SUFFICIENTLY CURED. 3. HOLD CONCRETE FOOTING BELOW GRADE OF FINISHED CONCRETE TO CREATE FINAL PAVING PATTERN AS SHOWN ON PLANS. DRAWN 12/2016 LOUCKS PLATE NO. 2038LOUCKS SITE AREA: 3.10 ± AC EXISTING IMPERVIOUS AREA: 2.72 ± AC (87.7%) PROPOSED IMPERVIOUS AREA: 2.06 ± AC (66.5%) SITE DATA PAVEMENT LEGEND CONCRETE SIDEWALK HEAVY DUTY CONCRETE PAVEMENT BITUMINOUS PAVEMENT PROPOSED BUILDING FFE-953.20 GFE-942.20 PROPOSED BUILDING FFE-953.20 GFE-942.20 25151 TRAV MAG950.66 25152TRAV MAG950.75 0.1% 2. 0 % 2.0 % 2. 0 % 9 5 1 95 2 950 948 949 951 947945944 9 5 0 94 6 94 7 9 4 8 9 4 9 95 1 950 951 952 953 10 . 0 % 1.0%1.0% 2.0% 2. 0 % 11 . 2 % 11 . 2 % 945 950 943 944 946 947 948 949 1. 6 % 1. 5 % 1.7% 1.4%1.5% 954 953 954 954 954 9 5 1 951 95 0 9 4 3 94 4 948 95 1 95 2 95 2 950 95 1                   4 : 1 5:1 4:1 6:1 1.0% 944 945 952 2.0 % 2. 3 % 2.3% 1.0%0.7% 1.3% 4.8% 95 2 95 2 95 2 0. 4 % 953 952 952 4.9% 3.9 % 95 2 95 2 95 1 953        95 1 1. 8 % 2. 0 % 1. 1 % 1. 0 % 4. 6 % 50.88 51.31 51.05 52.19 52.67 51.51 51.42 51.48 51.43 42.05 42.20 42.05 52.02 GW=942.90 TW=952.90 53.20 54.2053.2053.00 52.90 52.27 53.20 53.14 53.20 53.20 TW=952.00 42.20 49.0053.20 52.4052.90 52.87 42.10 42.10 44.75 48.41 47.98 48.70 49.1651.74 51.57 51.6551.90 51.90 51.90 51.82 52.15 48.37 50.82 51.12 50.6050.59 50.66 50.98 51.70 50.6553.13 53.18 50.15 53.53 53.76 54.61 54.50 53.45 50.39 55.03 51.53 52.5552.19 52.09 50.92 51.33 50.98 51.04 54.36 53.30 52.61 52.67 51.89 52.49 53.11 53.20 43.00 52.30 51.50 52.0052.64 52.50 50.7550.68 51.12 50.68 49.95 51.49 51.55 50.76 51.90 51.8451.00 52.00 51.9051.17 51.75 51.69 50.96 52.16 52.2051.64 50.74 50.56 45.12 48.36 GW=946.00 GW=946.25TW=951.50 TW=951.00 GW=951.00 TW=951.0053.14 52.64 52.64 50.56 50.03 52.00 52.54 52.90 52.90 52.33 TS=952.38 BS=953.13 53.14 51.75 51.11 50.91 50.85 49.7850.21 50.73 50.23 50.56 50.95 51.02 51.34 51.40 52.46 52.46 51.96 51.90 51.90 51.96 52.46 52.21 52.88 6. 0 % 4. 6 % 95 4 95 4 54.28 95 3 53.00 53.00 BS=952.95 TS=954.95 52.77 51.00 51.90 51.79 4.9%1.0%                  51.65 50.84   52.80  42.15 48.25 48.81 0.8% 2. 0 % 42.20 42.20 2. 1 % 4.5% 2. 5 % 2.0%1. 0 % 1. 5 % 52.47 TW=949.01 GW=948.75 TW=951.00 GW=949.06 TW=952.00 GW=951.75  53.20 51.23 BS=951.89 TS=953.14 E.O.F. 951.72 E.O.F. 951.32 E.O.F. 948.75 LOUCKS W: \ 2 0 2 4 \ 2 4 5 1 4 A \ c a d d D a t a \ C I V I L \ _ d w g S h e e t F i l e s \ C 3 - 1 G R A D I N G P L A N Pl o t t e d : 0 8 / 2 8 / 2 0 2 5 1 1 : 2 7 A M 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD QUALIFICATION APPLE VALLEY GASLIGHT APARTMENTS APPLE VALLEY, MN REAL ESTATE EQUITIES 579 Selby Avenue St. Paul, MN 55102 06/11/25 CHECK SET 06/18/25 CITY SUBMITTAL 08/07/25 CITY RE-SUBMITTAL 08/28/25 CITY RE-SUBMITTAL C1-1 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-3 SWPPP NOTES C4-1 STORM SEWER PLAN C4-2 WATERMAIN & SANITARY PLAN C8-1 CIVIL DETAILS C8-2 CIVIL DETAILS L1-1 LANDSCAPE PLAN L1-2 LANDSCAPE DETAILS Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE Project Lead Drawn By Checked By Loucks Project No. 49933 24514A PJD DDL PJD 08/28/25 - GRADING PLAN C3-1 1. SPOT ELEVATIONS REPRESENT FINISHED SURFACE GRADES, GUTTER/FLOW LINE, FACE OF BUILDING, OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. 2. ALL ACCESSIBLE ROUTES SHALL BE CONSTRUCTED WITH A CROSS SLOPE NOT EXCEEDING 2% AND A RUNNING SLOPE NOT EXCEEDING 5%. 3. AT TURNING POINTS ALONG THE ACCESSIBLE ROUTE THE PAVEMENT SHALL NOT EXCEED 2% IN ANY DIRECTION FOR AN AREA 60" IN DIAMETER. 4. ALL PUBLIC SIDEWALKS SHALL BE CONSTRUCTED WITH A CROSS SLOPE NOT EXCEEDING 2% AND A RUNNING SLOPE NOT EXCEEDING 5%. 5. CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH BASINS IN GUTTERS SHALL BE SUMPED 0.16 FEET. RIM ELEVATIONS SHOWN ON PLANS DO NOT REFLECT SUMPED ELEVATIONS. 6. REFER TO GEOTECHNICAL EVALUATION REPORT FOR AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS INCLUDING BUT NOT LIMITED TO: A. REUSE OF ON-SITE SOILS B. GROUNDWATER AND RECOMMENDATIONS FOR EXCAVATION DEWATERING. C. SITE GRADING AND SUBGRADE PREPARATION. D. PAVEMENTS AND EXTERIOR SLABS. E. TRENCH EXCAVATION AND BACKFILL. F. EXTERIOR UTILITY SUPPORTS. G. FROST PROTECTION. 7. GRADING, INCLUDING BUT NOT LIMITED TO EXCAVATION AND BACKFILL, OF THE INFILTRATION AREA(S) SHALL BE ACCOMPLISHED USING LOW-IMPACT EARTH-MOVING EQUIPMENT TO PREVENT COMPACTION OF THE UNDERLYING SOILS. SMALL TRACKED DOZERS AND BOBCATS WITH RUNNER TRACKS ARE RECOMMENDED. NO WHEELED MACHINES SHALL BE USED. 8. SOIL BENEATH THE INFILTRATION AREA(S) SHALL BE RIPPED WITH A TOOTHED BUCKET TO REMOVE SOIL INTERFACE PRIOR TO BACKFILL. 9. A FLOOD TEST OR DOUBLE RING INFILTROMETER TEST SHALL BE COMPLETED FOR THE INFILTRATION SYSTEM TO VERIFY INFILTRATION RATES ARE WITHIN THE ACCEPTABLE RANGE OF X.X IN/HR TO X.X IN/HR. 10. CITY AND WATERSHED SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO CONSTRUCTION OF STORMWATER BMPS. 11. ALL DISTURBED UNPAVED AREAS ARE TO RECEIVE MINIMUM OF 4 INCHES OF TOP SOIL AND SEED/MULCH OR SOD. THESE AREAS SHALL BE WATERED/MAINTAINED BY THE CONTRACTOR UNTIL VEGETATION IS ESTABLISHED. REFER TO THE LANDSCAPE PLANS, DETAILS AND SPECIFICATIONS FOR FINAL SITE STABILIZATION. 12. FOR SITE RETAINING WALLS "TW" EQUALS SURFACE GRADE AT TOP FACE OF WALL (NOT TOP OF WALL), "GW" EQUALS SURFACE GRADE AT WALL GRADE TRANSITION, AND "BW" EQUALS SURFACE GRADE AT BOTTOM FACE OF WALL (NOT BOTTOM OF BURIED WALL COURSES). 13. FOR SITE STAIRS, "TS" EQUALS SURFACE ELEVATION AT TOP OF STAIRS AND "BS" EQUALS SURFACE ELEVATION AT BOTTOM OF STAIRS. REFER TO SITE PLAN FOR NUMBER OF RISERS AND RISER HEIGHT. 14. STREETS MUST BE CLEANED AND SWEPT WHENEVER TRACKING OF SEDIMENTS OCCURS AND BEFORE SITES ARE LEFT IDLE FOR WEEKENDS AND HOLIDAYS. A REGULAR SWEEPING SCHEDULE MUST BE ESTABLISHED. 15. DUST MUST BE ADEQUATELY CONTROLLED. 16. SEE SWPPP FOR ADDITIONAL EROSION CONTROL NOTES AND REQUIREMENTS. 17. SEE UTILITY PLAN FOR WATERMAIN, STORM SEWER, AND SANITARY SEWER INFORMATION. 18. SEE SITE PLAN FOR CURB AND BITUMINOUS TAPER LOCATIONS. 19. REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR BUILDING ELEVATIONS. 20. THE CONTRACTOR ALONG WITH THE OWNER SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM GOVERNING AUTHORITIES, INCLUDING ANY CITY PERMITS AND THE NPDES PERMIT. 21. INSTALL EROSION CONTROL AND TREE PROTECTION MEASURES BEFORE BEGINNING SITE GRADING ACTIVITIES. SOME EROSION CONTROLS SUCH AS BALE CHECKS AND TEMPORARY SILT PONDS MAY BE INSTALLED AS GRADING OCCURS IN SPECIFIC AREAS. MAINTAIN EROSION CONTROLS THROUGHOUT THE GRADING PROCESS AND REMOVE WHEN TURF HAS BEEN ESTABLISHED. 22. PER NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM/STATE DISPOSAL SYSTEM (NPDES/SDS) REQUIREMENTS, THE WASHOUT AND CLEANOUT OF STUCCO, PAINT, CONCRETE, FORM RELEASE OILS, CURING COMPOUNDS, AND OTHER CONSTRUCTION MATERIALS SHALL BE PROPERLY CONTAINED AND DISPOSED OF. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND USING APPROVED METHODS OF CONTAINMENT SUCH AS PRE-FABRICATED WASHOUT CONTAINERS, CONCRETE WASHOUT TOTE, READY MIX TRUCKS WITH SELF-CONTAINED CHUTE CLEANOUT, ETC. 23. CONTRACTOR SHALL PROVIDE AS-BUILT INFORMATION OF GRADING ACTIVITIES AS NEEDED PER APPLICABLE PERMIT REQUIREMENTS AND/OR DEVELOPMENT AGREEMENTS. GRADING, DRAINAGE & EROSION CONTROL NOTES PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN    PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING  DIRECTION OF FLOW 1.0% 972.5 N SCALE IN FEET 0 30 60 WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. AREA NOTES EXISTING TOTAL AREA = 135,009 SQ.FT. OR 3.099 AC. IMPERVIOUS SURFACE AREA = 118,443 SQ.FT. OR 2.719 AC. = 87.7% PERVIOUS SURFACE AREA = 16,566 SQ.FT. OR 0.380 AC. = 12.3% OVERALL CURVE NUMBER = 93 PROPOSED TOTAL AREA = 135,009 SQ.FT. OR 3.577 AC. IMPERVIOUS SURFACE AREA = 89,799 SQ.FT. OR 2.127 AC. = 66.5% PERVIOUS SURFACE AREA = 45,230 SQ.FT. OR 1.450 AC. = 33.5% OVERALL CURVE NUMBER = 86                                                                                                                     3 IL 3 IL 4 SK 3 NO 3 NO 2 PE 1 NO 2 BL 3 BL 3 PO 2 PO 3 PE 2 PO  3 BL 4 BS 1 IL 2 SK 2 IH 3 PE 2 KC 3 GL 3 IHD 18 BE 23 BE 5 GF  9 AC 7 IHD 8 ALC 4 IHD 4 AC 4 WS 4 AC 8 IHD 8 ALC 6 WS 4 AC 25 FG 6 GF    18 GF 16 BE 3 ALC 4 ALC 2 IHD 14 FG  4 GF 7 AC 6 IHD 9 TY 9 AC 4 IHD 4 ALC 4 WS 4 AC 4 IHD  10 ALC 7 IHD 8 AC 6 WS 2 IHD 9 AR 3 IHD 6 IHD 3 AR 29 BAD 5 INH 42 BAD 20 FG 11 FG 19 BE 5 Mj2 1 Mj2 1 INH 5 TY 2 INH 5 AJ 7 MJJ 34 BAD  9 AJ 61 ML 1 IH 1 SK 3 SSC 8 IHD 3 AC 9 WS 2 IHD 3 ALC 10 TY 14 BE 9 ALC 6 IHD 16 FG  6 GF 6 LN 6 LIB 3 ALC 5 ALC 1 IHD METAL EDGER, TYP. METAL EDGER, TYP. METAL EDGER, TYP. METAL EDGER, TYP. VINYL FENCE, SEE DETAIL 6/L2-1 ORNAMENTAL FENCE, SEE DETAIL 7/L2-1 WIREWORKS FENCE, SEE DETAIL 9-10/L2-1 ORNAMENTAL FENCE, SEE DETAIL 7/L2-1 30' SIGHT TRIANGLE 30' SIGHT TRIANGLE CODE QTY BOTANICAL NAME COMMON NAME CONT.SIZE DECIDUOUS TREES IH 3 GLEDITSIA TRIACANTHOS `IMPCOLE` TM IMPERIAL HONEYLOCUST 2.5" CAL.B&B SK 7 GLEDITSIA TRIACANTHOS `SKYCOLE`SKYLINE HONEYLOCUST 2.5" CAL.B&B KC 2 GYMNOCLADUS DIOICA KENTUCKY COFFEETREE 2.5" CAL.B&B PO 7 PRUNUS CERASIFERA 'OAKVILLE CRIMSON SPIRE'OAKVILLE CRIMSON SPIRE PURPLE PLUM 2.5" CAL.B&B BL 8 TILIA AMERICANA `BOULEVARD`BOULEVARD LINDEN 2.5" CAL.B&B GL 3 TILIA CORDATA `GREENSPIRE`GREENSPIRE LINDEN 2.5" CAL.B&B PE 8 ULMUS AMERICANA `PRINCETON`PRINCETON ELM 2.5" CAL.B&B 38 SUBTOTAL: EVERGREEN TREES BS 4 PICEA GLAUCA `DENSATA` FULL FORM BLACK HILLS SPRUCE 6` HEIGHT B&B NO 7 PINUS RESINOSA FULL FORM NORWAY PINE 6` HEIGHT B&B 11 SUBTOTAL: ORNAMENTAL TREES SSC 3 MALUS X `SPRING SNOW`SPRING SNOW CRABAPPLE 1.5" CAL.B&B IL 7 SYRINGA RETICULATA `IVORY SILK`IVORY SILK TREE LILAC 1.5" CAL.B&B 10 SUBTOTAL: SHRUBS AC 52 ARONIA MELANOCARPA `MAGIC CARPET`AUTUMN MAGIC CHOKEBERRY 5 GAL CONT. IHD 73 CORNUS ALBA `BAILHALO` TM IVORY HALO DOGWOOD 5 GAL CONT. INH 8 HYDRANGEA ARBORESCENS `INCREDIBALL`INCREDIBALL HYDRANGEA 5 GAL CONT. LN 6 PHYSOCARPUS OPULIFOLIUS `LITTLE DEVIL` TM LITTLE DEVIL NINEBARK 5 GAL CONT. GF 39 RHUS AROMATICA `GRO-LOW`GRO-LOW FRAGRANT SUMAC 5 GAL CONT. ALC 57 RIBES ALPINUM ALPINE CURRANT 5 GAL CONT. WS 29 SYMPHORICARPOS ALBUS WHITE SNOWBERRY 5 GAL CONT. ML 61 SYRINGA PATULA `MISS KIM`MISS KIM LILAC 5 GAL CONT. 325 SUBTOTAL: PERENNIALS BAD 105 HEMEROCALLIS X `BAJA`BAJA DAYLILY 1 GAL CONT. BE 90 RUDBECKIA FULGIDA `GOLDSTRUM`BLACK EYED SUSAN 1 GAL CONT. 195 SUBTOTAL: CONIFEROUS SHRUBS MJJ 7 JUNIPERUS CHINENSIS `MONLEP`MINT JULEP JUNIPER 5 GAL CONT. AJ 14 JUNIPERUS HORIZONTALIS `PLUMOSA COMPACTA`ANDORRA COMPACT JUNIPER 5 GAL CONT. Mj2 6 JUNIPERUS SCOPULORUM `MEDORA` FULL FORM MEDORA JUNIPER 15 GAL 4` HGT TY 24 TAXUS X MEDIA `TAUNTON`TAUNTON YEW 5 GAL CONT. 51 SUBTOTAL: GRASSES AR 12 ANDROPOGON GERARDII 'RED OCTOBER'RED OCTOBER BIG BLUESTEM 5 GAL CONT. FG 86 CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER`FEATHER REED GRASS 1 GAL CONT. LIB 6 SCHIZACHYRIUM SCOPARIUM LITTLE BLUESTEM 1 GAL CONT. 104 SUBTOTAL: SYMBOL CODE BOTANICAL NAME COMMON NAME CONT.SIZE GROUND COVERS SM 1 CRUSHED GRAY ROCK 1/4" MINUS 3" DEPTH STONE MULCH NONE Hwm HARDWOOD MULCH - 3" DEPTH OVER GEOTEXTILE FABRIC HARDWOOD MULCH NONE SOD TURF SOD SOD PLANT SCHEDULE LOUCKS W: \ 2 0 2 4 \ 2 4 5 1 4 A \ C A D D D A T A \ L A N D S C A P E \ _ d w g S h e e t F i l e s \ L 1 - 1 L A N D S C A P E P L A N Pl o t t e d : 0 8 / 2 8 / 2 0 2 5 1 1 : 4 1 A M 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD QUALIFICATION APPLE VALLEY GASLIGHT APARTMENTS APPLE VALLEY, MN REAL ESTATE EQUITIES 579 Selby Avenue St. Paul, MN 55102 06/11/25 CHECK SET 06/18/25 CITY SUBMITTAL 08/07/25 CITY RE-SUBMITTAL 08/28/25 CITY RE-SUBMITTAL C1-1 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-3 SWPPP NOTES C4-1 STORM SEWER PLAN C4-2 WATERMAIN & SANITARY PLAN C8-1 CIVIL DETAILS C8-2 CIVIL DETAILS L1-1 LANDSCAPE PLAN L1-2 LANDSCAPE DETAILS Douglas D. Loken - LA Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. 45591 Project Lead Drawn By Checked By Loucks Project No.24514A PJD DDL DDL 08/28/25 - N SCALE IN FEET 0 30 60 LANDSCAPE PLAN L1-1 WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID. HE SHALL INSPECT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS RELATING TO THE NATURE AND SCOPE OF WORK. VERIFY LAYOUT AND ANY DIMENSIONS SHOWN AND BRING TO THE ATTENTION OF THE LANDSCAPE ARCHITECT ANY DISCREPANCIES WHICH MAY COMPROMISE THE DESIGN AND / OR INTENT OF THE PROJECT'S LAYOUT. ASSURE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS GOVERNING THE WORK OR MATERIALS SUPPLIED. CONTRACTOR SHALL PROTECT ALL EXISTING ROADS, CURBS / GUTTERS, TRAILS, TREES, LAWNS AND SITE ELEMENTS DURING PLANTING OPERATIONS. ANY DAMAGE TO SAME SHALL BE REPAIRED AT NO COST TO THE OWNER. CONTRACTOR SHALL VERIFY ALIGNMENT AND LOCATION OF ALL UNDERGROUND AND ABOVE GRADE UTILITIES. CONTRACTOR TO PROVIDE THE NECESSARY PROTECTION FOR THE UTILITIES BEFORE CONSTRUCTION / MATERIAL INSTALLATION BEGINS. CONTRACTOR TO NOTIFY GENERAL CONTRACTOR OF ANY CONCERNS PRIOR TO INSTALLATION OF PLANTINGS. EXISTING CONTOURS, TRAILS, VEGETATION, CURB / GUTTER AND OTHER EXISTING ELEMENTS BASED UPON INFORMATION SUPPLIED TO LANDSCAPE ARCHITECT BY OTHERS. CONTRACTOR SHALL VERIFY ANY AND ALL DISCREPANCIES PRIOR TO CONSTRUCTION AND NOTIFY LANDSCAPE ARCHITECT OF SAME. THE ALIGNMENT AND GRADES OF THE PROPOSED WALKS, TRAILS AND / OR ROADWAYS ARE SUBJECT TO FIELD ADJUSTMENT REQUIRED TO CONFORM TO LOCALIZED TOPOGRAPHIC CONDITIONS AND TO MINIMIZE TREE REMOVAL AND GRADING. ANY CHANGE IN ALIGNMENT MUST BE APPROVED BY LANDSCAPE ARCHITECT. VERIFY EXISTING / PROPOSED IRRIGATION SYSTEM LAYOUT AND CONFIRM COMPLETE LIMITS OF IRRIGATION PRIOR TO SUPPLYING SHOP DRAWINGS. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN IRRIGATION LAYOUT PLAN AND SPECIFICATION AS A PART OF THE SCOPE OF WORK WHEN BIDDING. THESE SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO ORDER AND / OR INSTALLATION. IT SHALL BE THE LANDSCAPE CONTRACTORS RESPONSIBILITY TO INSURE THAT ALL SODDED / SEEDED AND PLANTED AREAS ARE IRRIGATED PROPERLY, INCLUDING THOSE AREAS DIRECTLY AROUND AND ABUTTING BUILDING FOUNDATION. THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE OWNER WITH AN IRRIGATION SCHEDULE APPROPRIATE TO THE PROJECT SITE CONDITIONS AND TO PLANT MATERIAL GROWTH REQUIREMENTS. IRRIGATION SYSTEM IS NOT TO SPRINKLE ACROSS PAVEMENT NOR SHALL THE SYSTEM SPRINKLE THE BUILDING. THE SYSTEM SHALL INCORPORATE A RAIN SENSOR INTO IRRIGATION SYSTEM. PLANTINGS OUTSIDE THE LIMITS OF IRRIGATION ARE TO BE WATERED REGULARLY UNTIL PLANTING / SOD / SEED HAS BEEN ESTABLISHED. GENERAL NOTES IRRIGATION NOTES LANDSCAPE CACULATIONS: FOR COMMERCIAL PROJECTS IN APPLE VALLEY THE MINIMUM LANDSCAPE VALUE IS TO BE 1.5% MIN. OF THE TOTAL TOTAL ESTIMATED PROJECT VALUE: $32 MILLION ESTIMATED LANDSCAPE VALUE REQUIRED: $480,000 ESTIMATED LANDSCAPE VALUE PROVIDED: $480,000 (SEE CHART BELOW) REQUIRED MINIMUM LANDSCAPE VALUE: 1.5% OF PROJECT VALUE = $480,000 OVERSTORY TREES 38 TREES X $700) $26,600 CONIFEROUS TREES (11 TREES X $600) $6,600 ORNAMENTAL TREES (10 TREES X $500) $5,000 SHRUBS - 339 x $70 $23,730 EVERGREEN SHRUBS - 52 X $100 $5,200 PERENNIALS 196 X $40 $7,840 GRASSES 174 X $40 $6,960 IRRIGATION $50,000 COURTYARD (FURNITURE, PLANTERS, DECORATIVE PAVING) $25,000 DOG RUN (CONCRETE EDGER, ARTIFICIAL TURF, DOG SIGNAGE/TRASH) $30,000 TOT LOT (CONCRETE EDGER, PIP RUBBER, PLAYGROUND) $50,000 FENCING $80,000 LANDSCAPE EDGING $15,000 LANDSCAPE ROCK $5,000 LANDSCAPE HARDWOOD MULCH $3,000 BIKE RACKS $6,000 MISCELLANEOUS IMPROVEMENTS $134,070 (ADDITIONAL SITE FURNISHINGS, PERGOLA STRUCTURE, PLAYGROUND SHADE STRUCTURE) TOTAL $480,000 MINIMUM LANDSCAPE VALUE COST OPINION LOUCKS W: \ 2 0 2 4 \ 2 4 5 1 4 A \ c a d d D a t a \ L A N D S C A P E \ _ d w g S h e e t F i l e s \ L 2 - 1 L A N D S C A P E D E T A I L S Pl o t t e d : 0 8 / 2 8 / 2 0 2 5 1 1 : 3 5 A M 7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD QUALIFICATION APPLE VALLEY GASLIGHT APARTMENTS APPLE VALLEY, MN REAL ESTATE EQUITIES 579 Selby Avenue St. Paul, MN 55102 06/11/25 CHECK SET 06/18/25 CITY SUBMITTAL 08/07/25 CITY RE-SUBMITTAL 08/28/25 CITY RE-SUBMITTAL C1-1 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-3 SWPPP NOTES C4-1 STORM SEWER PLAN C4-2 WATERMAIN & SANITARY PLAN C8-1 CIVIL DETAILS C8-2 CIVIL DETAILS L1-1 LANDSCAPE PLAN L1-2 LANDSCAPE DETAILS Douglas D. Loken - LA Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. 45591 Project Lead Drawn By Checked By Loucks Project No.24514A PJD DDL DDL 08/28/25 - LANDSCAPE DETAILS L2-1 2x ROOT BALL WIDTH SET PLANT ON UNDISTRUBED NATIVE SOIL SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING EDGE CONDITION VARIES WOOD STAKE BACKFILL WITH IN SITU TOPSOIL MULCH - 4" DEEP. NO MULCH IN CONTACT WITH TRUNK - SEE NOTES OR SPECS. ROOT FLARE EVEN WITH OR JUST ABOVE GRADE SAFETY FLAGGING - ONE PER WIRE TREE WRAP TO FIRST BRANCH 16"X2" POLYPROPYLENE OR POLYETHYLENE STRAP NOTES: 1. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL TREES IN A PLUMB POSITION THROUGH THE WARRANTY PERIOD. STAKING IS SUGGESTED, BUT NOT REQUIRED. ANY STAKING MUST CONFORM WITH PRACTICES AS DEFINED IN A.N.A. GUIDELINES FOR STANDARD PRACTICES. 2. PRUNE DAMAGED AND CROSSING BRANCHES AFTER PLANTING IS COMPLETE. 3. CUT BACK WIRE BASKET. 4. WATER TREE THOROUGHLY DURING PLANTING OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND SATURATE SOIL WITH WATER. DO NOT COMPACT MORE THAN NECESSARY TO MAINTAIN PLUMB. 5. CONTRACTOR IS RESPONSIBLE FOR TESTING PERCOLATION RATES PRIOR TO PLANTING. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF POOR DRAINAGE EXISTS. DETAIL - DECIDUOUS TREE 3/4" = 1'-0" CUT ROPES AND EXPOSE TOP 1/3 OF BURLAP BALL. REMOVE NON-BIODEGRADABLE MATERIAL. PLANT-TREE-011 2 x ROOT BALL WIDTH NOTES: 1. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL TREES IN A PLUMB POSITION THROUGH THE WARRANTY PERIOD. STAKING IS SUGGESTED, BUT NOT REQUIRED. ANY STAKING MUST CONFORM WITH PRACTICES AS DEFINED IN A.N.A. GUIDELINES FOR STANDARD PRACTICES. 2. PRUNE ANY DAMAGED BRANCHES AFTER PLANTING IS COMPLETE. 3. WATER TREE THOROUGHLY DURING PLANTING OPERATIONS. PLACE BACKFILL IN 8-12" LIFTS AND SATURATE SOIL WITH WATER. DO NOT COMPACT MORE THAN NECESSARY TO MAINTAIN PLUMB. 4. CONTRACTOR IS RESPONSIBLE FOR TESTING PERCOLATION RATES PRIOR TO PLANTING. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF POOR DRAINAGE EXISTS. DETAIL - CONIFEROUS TREE 3/4" = 1'-0" SET PLANT ON UNDISTRUBED NATIVE SOIL SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING EDGE CONDITION VARIES WOOD STAKE BACKFILL WITH IN SITU TOPSOIL MULCH - 4" DEEP. NO MULCH IN CONTACT WITH TRUNK - SEE NOTES OR SPECS. SAFETY FLAGGING - ONE PER WIRE 16"X2" POLYPROPYLENE OR POLYETHYLENE STRAP CUT ROPES AND EXPOSE TOP 1/3 OF BURLAP BALL. REMOVE NON-BIODEGRADABLE MATERIAL. 2 PLANT-TREE-02 NOTES: LOOSEN ROOTS OF ALL CONTAINERIZED PLANTS. SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING EDGE VARIES - REFER TO PLAN EDGING MATERIAL - SEE NOTES OR SPEC. LANDSCAPE FABRIC - SEE NOTES OR SPEC. MULCH - 3" DEPTH - SEE NOTES OR SPEC. PLANTING SOIL - SEE NOTES OR SPEC. SHRUBS TO BE PLACED SO THAT TOP OF CONTAINER SITS FLUSH WITH PROPOSED GRADE DETAIL - SHRUB PLANTING 1" = 1'-0" REFER TO SCHEDULE 18" MIN. PREPARE BED A MIN. 4" DEEPER THAN ROOT BALL PLANT-SHRB-013 VARIES SEE SCHEDULE FOR SPACING NOTE: LOOSEN ROOTS OF PLANT MATERIAL PRIOR TO PLANTING PLANTING SOIL - SEE NOTES EDGE VARIES - REFER TO PLAN EDGING MATERIAL - SEE NOTES MULCH - 3" MIN. DEPTH - SEE NOTES PLANTING - PERENNIAL 1" = 1'-0"PLANT-PER-014 ROCK MULCH AT 4" MIN. DEPTH; EXPOSE NO FABRIC ; SEE SCHEDULE FOR COLOR WOVEN GEOTEXTILE FABRIC. OVERLAP 6" MINIMUM; SECURE IN PLACE WITH POLY FABRIC STAPLES PREPARED SUBGRADE LM-01 - ROCK MULCH 1 1/2" = 1'-0"HARD-LM-035 VINYL FENCE NTS 8' TYP 12" DIAM HARD-LM-036 AEGIS II ORNAMENTAL STEEL FENCE NTS VARIES - SEE PLAN 3 34" 1 34" FORERUNNER RAIL 1 34" FORERUNNER RAIL CONFIRM POST SIZE WITH MNFR. 1" X 14 GA. SQUARE PICKET COMPACTED OR UNDISTURBED GRADE HARD-LM-037 10 11 2 3/8"1'-4 1/2" SURFACE MOUNT PER MANUFACTURER'S RECOM\MENDATIONS PAVING PER PLANS AGGREGATE BASE 2-3/8" SCH. 40 PIPE COVER PLATE COMPACTED SUBGRADE BIKE RACK DETAIL 3/4" = 1'-0"8 PROJ-OB-12 CONCRETE CURBADD CONTROL JOINTS EVERY 48" MIN. TWO #4 REBAR CONTINUOUS ORNAMENTAL FENCE (SURFACE MOUNT) SEE DETAIL GRAVEL DOG RUN SURFACE CONCRETE CURB @ DOG RUN 1/2" = 1'-0"9 DETAIL-FILE CONCRETE PLAYGROUND EDGER 8x18PLAYEDGE-WOOD.dwgSCALE: 3/4" = 1'-0"12 NDDVZLOVRQDUFKLWHFWV 9DOOH\6WDWLRQ$SDUWPHQWV&29(5 *DVOLJKW'U$SSOH9DOOH\01 9DOOH\6WDWLRQ$SDUWPHQWV *DVOLJKW'U$SSOH9DOOH\01   '1 83 '1 83 81,76#6725,(6 IWð *DUDJH IWð &RPP5RRP /(9(/ *$5$*( (175< IWð &RUH IWð 6WDLU' IWð &RUH IWð 6WDLU$ IWð 6WDLU% IWð 6WDLU& IWð &RUULGRU IWð .LGV 5RRP IWð 2IILFHV IWð 3DFNDJH5RRP IWð 9HVWLEXOH IWð /REE\ IWð *\P                 75$16)250(5 3$7,2 727/27 /(9(/ *$5$*((175< '2*581 9(+,&/($&&(66 /(9(/*$5$*( (175< %,.( 3$5.,1* %,.( 3$5.,1* (175< (175< IWð &RUULGRU 75$6+ 3$'             9(+,&/( $&&(66       IWð 8QLW IWð 8QLW *5 , / / (9 (9 (9 (9 IWð 8QLW     IWð 8QLW IWð 8QLW (9 (9(9(9 (9 (9 IWð %DWK IWð 8QLW IWð 8QLW IWð 8QLW IWð 8QLW IWð 8QLWIWð %DWK IWð 0DLQW2IILFH IWð 0DLO   IWð :RUN5RRP NDDVZLOVRQDUFKLWHFWV 9DOOH\6WDWLRQ$SDUWPHQWV)/2253/$16 /(9(/ *DVOLJKW'U$SSOH9DOOH\01 1  /HYHO      .(<3/$1 1  727$/)$&$'(6)6) 352326('0$7(5,$/6 $&096)  &086)  */$=,1*6)  /$36,',1*6)            727$/)$&$'(6)6) 352326('0$7(5,$/6 $&096)   &086)  */$=,1*6)  /$36,',1*6)               727$/)$&$'(6)6) 352326('0$7(5,$/6 $&096)  &086)  */$=,1*6)  /$36,',1*6)           727$/)$&$'(6)6) 352326('0$7(5,$/6 $&096)  &086)  */$=,1*6)  /$36,',1*6)           NDDVZLOVRQDUFKLWHFWV 9DOOH\6WDWLRQ$SDUWPHQWV(;7(5,25(/(9$7,216 *DVOLJKW'U$SSOH9DOOH\01   1RUWK(OHYDWLRQB6'   (DVW(OHYDWLRQB6'   6RXWK(OHYDWLRQB6'   1RUWK(OHYDWLRQB6' 727$/)$&$'(6)6) 352326('0$7(5,$/6 $&096)  &086)  */$=,1*6)  /$36,',1*6)             727$/)$&$'(6)6) 352326('0$7(5,$/6 $&096)  &086)  */$=,1*6)  /$36,',1*6)                .(<3/$1 1 $UHDVI NDDVZLOVRQDUFKLWHFWV 9DOOH\6WDWLRQ$SDUWPHQWV(;7(5,25(/(9$7,216 *DVOLJKW'U$SSOH9DOOH\01   6RXWK(OHYDWLRQB6'   :HVW(OHYDWLRQB6'   %XLOGLQJ6LJQDJH NDDVZLOVRQDUFKLWHFWV 9DOOH\6WDWLRQ$SDUWPHQWV(;7(5,250$7(5,$/6 *DVOLJKW'U$SSOH9DOOH\01 (;7(5,250$7(5,$/6 0DWHULDO 0DUN 'HVFULSWLRQ ,PDJH $UHD 3HUFHQWDJH  6SOLWIDFH&08*ODFLDO:KLWH IWò   6WRQH9HQHHU&XOWXUHG6WRQH+HZQ6WRQH )RXQGDWLRQ IWò   6LGLQJ-DPHV+DUGLH$OWHUQDWLQJ/DS6PRRWK $UFWLF:KLWH IWò   6LGLQJ-DPHV+DUGLH$OWHUQDWLQJ/DS6PRRWK 1LJKW*UD\ IWò   9LQ\O:LQGRZ IWò  IWò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| www.transportationcollaborative.com | To: Blaine Barker, Senior Development Associate Real Estate Equities From: Matt Pacyna, PE, Principal Transportation Collaborative & Consultants, LLC Date: August 20, 2025 Subject: Valley Station Apartments Traffic and Parking Review INTRODUCTION TC2 conducted a traffic and parking review for the proposed Valley Station Apartments development at the former Appley Valley Transit Station park-and-ride as shown in Figure 1. The site, which is currently vacant, is in the southeast quadrant of the 155th Street and Gaslight Drive intersection. The proposed development is a 144-unit workforce housing apartment complex, which includes a combination of 1-, 2-, and 3-bedroom units and a total of 240 parking spaces (162 garage and 78 surface lot). The main objectives of the study are to quantify existing traffic and parking conditions within the study area, evaluate potential impacts associated with the proposed development, and recommend improvements, if necessary, to ensure safe and efficient operations for all users. The following study assumptions, methodology, and findings are offered for consideration. Figure 1 Subject Site Subject Site Ga r r e t t Av e Ce d a r A v e ( C R 23 ) Apple Valley Transit Station 153rd St Ga s l i g h t D r 155th St Ga l a x ie Av e Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 2 EXISTING CONDITIONS Existing conditions were reviewed within the study area to establish current traffic conditions to help determine impacts associated with the proposed development. The evaluation of existing conditions included collecting traffic volumes, observing transportation characteristics, reviewing crash history, and analyzing intersection capacity, which are described in the following sections. Traffic Volumes Vehicular intersection turning movement and pedestrian / bicyclist counts were collected on Wednesday, July 30, 2025 from 6 a.m. to 7 p.m. at the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection. In addition, a.m. (7-9 a.m.) and p.m. (4-6 p.m.) peak period counts were collected at the 155th Street / East Apple Valley Transit Station and 153rd Street / Gaslight Drive intersections. The a.m. and p.m. peak hours within the study area represent 7 to 8 a.m. and 4:30 to 5:30 p.m. Average daily traffic (ADT) volumes were provided by MnDOT or estimated based on the 13-hour traffic count collected. Note that there was a total of 35 north-south pedestrians that crossed 155th Street at Gaslight Drive between 6 a.m. and 7 p.m. Transportation Characteristics Observations were conducted within the study area to identify various transportation characteristics such as roadway geometry, traffic controls, speed limits, and multimodal facilities. A general overview of key roadways within the study area is as follows: • 155th Street – a 2-lane undivided minor collector roadway with no turn lanes within the study area. There is sidewalk along both sides of the roadway and the speed limit is 30-mph. • Gaslight Drive – a 3-lane undivided local roadway with a center two-way left-turn lane. There is sidewalk along both sides of the roadway and the speed limit is 30-mph. The north approach of the 155th Street / Gaslight Drive intersection is the primary access to the Apple Valley Transit Station. All study intersections are two-way stop controlled. Existing geometrics, traffic controls, and volumes within the study area are shown in Figure 2. Crash History Five (5) years of crash history were reviewed from July 1, 2020 through June 30, 2025 using MnDOT’s Crash Mapping Analysis Tool (MnCMAT), which identified one (1) intersection-related crash at the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection. The accident was an angle-type crash that resulted in property damage only. At this level of crash frequency, there does not appear to be any existing safety or crash issues at the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection. Intersection Capacity Intersection capacity was evaluated using Synchro / SimTraffic Software (version 11), which uses methods outlined in the Highway Capacity Manual, 6th Edition. The software is used to develop calibrated models that simulate observed traffic operations, account for peaking characteristics, and identify key metrics such as intersection Level of Service (LOS) and queues. These models incorporate collected traffic, pedestrian, and bicyclist volumes, traffic controls, heavy commercial vehicle activity (i.e., buses and trucks), and driver behavior factors. Valley Station Apartments Traffic and Parking Review Existing Conditions 88 (15)24 (81)25 (69) 33 (9)31 (23)11 (58) 2 2 ( 2 8 ) 5 5 ( 5 ) 1 3 ( 3 4 ) 8 ( 4 0 ) 9 ( 1 0 0 ) 8 ( 3 8 ) 0 (0)45 (153)0 (0) 0 (0)75 (90)0 (0) 0 ( 0 ) 0 ( 0 ) 0 ( 0 ) 0 ( 0 ) 0 ( 0 ) 0 ( 3 ) 21 ( 2 9 ) 31 ( 7 1 ) 79 ( 3 8 ) 76 ( 1 2 2 ) 1 5 ( 1 0 1 ) 2 5 ( 1 0 6 ) 2,600 2,100 2 , 5 0 0 1, 2 0 0 155th St G a s l i g h t D r Ce d a r A v e ( C R 2 3 ) 153rd St 157th St Figure 2 Legend AM Peak Hour VolumePM Peak Hour VolumeEstimated ADT VolumeStop Sign XXX(XXX)X,XXX N Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 4 Level of Service (LOS) quantifies how an intersection is operating. Intersections are graded from LOS A to LOS F, which corresponds to the average delay per vehicle values shown. LOS A indicates the best traffic operation, while LOS F indicates an intersection where demand exceeds capacity. An overall intersection LOS A though LOS D is generally considered acceptable in the study area. For side-street stop-controlled intersections, special emphasis is given to providing an estimate for the level of service of the side-street approach. Traffic operations at an unsignalized intersection with side- street stop control can be described in two ways. First, consideration is given to the overall intersection level of service, which accounts for the total number of vehicles entering the intersection and the capability of the intersection to support the volumes. Second, it is important to consider the delay on the minor approach. Since the mainline does not have to stop, most delay is attributed to the side-street approaches. It is typical of intersections with higher mainline traffic volumes to experience high-levels of delay (i.e., poor levels of service) on the side-street approaches, but an acceptable overall intersection level of service during peak hour conditions. The existing intersection capacity analysis results, summarized in Table 1, indicate that all study intersections and approaches operate at an acceptable LOS B or better during the typical weekday a.m. and p.m. peak hours. Peak existing queues generally range between one (1) and two (2) vehicles. Thus, there are no significant existing operational issues from an intersection capacity perspective. Table 1 Existing Intersection Capacity Study Intersection Traffic Control Level of Service (Delay) AM Peak Hour PM Peak Hour Gaslight Drive & 155th Street / Transit Access SSS A / B (13) A / B (13) Gaslight Drive & West Site Access SSS A / A (0) A / A (0) Gaslight Drive & 157th Street SSS A / B (10) A / B (11) 155th Street & Transit Access / North Site Access SSS A / A (0) A / B (11) SSS – Side-Street-Stop Level of Service Average Delay / Vehicles Unsignalized Intersections Signalized Intersections A < 10 seconds < 10 seconds B 10 to 15 seconds 10 to 20 seconds C 15 to 25 seconds 20 to 35 seconds D 25 to 35 seconds 35 to 55 seconds E 35 to 50 seconds 55 to 80 seconds F > 50 seconds > 80 seconds Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 5 PROPOSED DEVELOPMENT The proposed development site, which is a former Apple Valley Transit Station park-and-ride, is currently vacant and in the southeast quadrant of the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection. The proposed development is a 144-unit workforce housing apartment complex, which includes a combination of unit types. There is planned to be 35 1-bedroom, 72 2-bedroom, and 37 3-bedroom units. A total of 240 parking spaces are proposed, which includes 162 garage and 78 surface lot spaces. For study purposes, the project was assumed to be open for residents in 2027. Access to the site will be provided in two locations. One access to 155th Street is planned in the current location across from the Apple Valley Transit Station east access, while the other access is planned along Gaslight Drive approximately 200 feet south of 155th Street. The existing southernmost access to the former Apple Valley Transit Station park-and-ride will be removed as part of the project. TRAFFIC FORECASTS Traffic forecasts were developed for year 2028 conditions, which represents one (1) year after opening. The forecasts account for general background growth and trip generation from the proposed development. The following information summarizes the traffic forecast development process. Background Growth To account for general background growth in the study area, an annual growth rate of one (1) percent was applied to the existing traffic volumes to develop year 2028 background traffic forecasts. This growth rate is consistent with historical growth trends in the area. Trip Generation A trip generation estimate for the proposed development, shown in Table 2, was created using the ITE Trip Generation Manual, 11th Edition. The estimate was developed using two independent variables (i.e., units and bedrooms) to illustrate the range of potential trip generation. Based on the average of the two variables, the proposed development is expected to generate 102 a.m. peak hour (28 in / 74 out), 73 p.m. peak hour (43 in / 30 out), and 870 daily (435 in / 435 out) trips. No reductions for walking, biking, or transit were applied to provide a conservative estimate, however it would be reasonable to assume that a portion of residents would regularly use the adjacent Apple Valley Transit Station. The Affordable Housing trip generation rate is slightly higher than the Multifamily Housing (Mid-Rise) rate. Table 2 Trip Generation Summary Land Use Type (ITE Code) Size AM Peak Hour PM Peak Hour Daily In Out In Out Affordable Housing (223) 144 units 21 51 39 27 694 Affordable Housing (223) 290 bedrooms 34 97 46 32 1,046 Total Trips (Average of Both Variables) 28 74 43 30 870 Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 6 The proposed development trips were distributed throughout the study area using the directional distribution shown in Figure 3, which is based on a combination of existing area travel patterns and engineering judgment. The resultant year 2028 build conditions, which accounts for both the general background growth and trips from the proposed development, are illustrated in Figure 4. YEAR 2028 CONDITIONS To understand impacts associated with the proposed development, an intersection capacity analysis was completed for year 2028 conditions. Results of the year 2028 intersection capacity analysis, shown in Table 3, indicate that all study intersections and approaches are expected to continue to operate at LOS B or better during the typical weekday a.m. and p.m. peak hours. Peak queues will also continue to generally range between one (1) and two (2) vehicles. Thus, there are no significant operational issues related to the proposed development from an intersection capacity perspective. Table 3 Year 2028 Intersection Capacity Study Intersection Traffic Control Level of Service (Delay) AM Peak Hour PM Peak Hour Gaslight Drive & 155th Street / Transit Access SSS A / B (13) A / B (14) Gaslight Drive & West Site Access SSS A / B (10) A / B (11) Gaslight Drive & 157th Street SSS A / B (10) A / B (11) 155th Street & Transit Access / North Site Access SSS A / B (10) A / B (11) SSS – Side-Street-Stop PARKING REVIEW The proposed 144-unit development is planning a total of 240 parking spaces, which includes 162 garage and 78 surface lot spaces. The required amount of parking based on Apple Valley City Code (Section 155.379) is 1.5 parking spaces per dwelling unit and one (1) garage space per unit. This equates to a minimum requirement of 360 spaces, of which 144 should be garage spaces. The proposed development does not meet the minimum required spaces per Apple Valley City Code. However, at the request of City staff, a more detailed parking assessment was conducted to determine if the proposed parking supply is sufficient to accommodate the expected parking demand. The following information summarizes the additional parking review approach and findings. Parking Demand A parking demand estimate for the proposed development, shown in Table 4, was created using the ITE Parking Generation Manual, 6th Edition. The estimate was based on ITE Land Use Code 223 – Affordable Housing and developed using two independent variables (i.e., units and bedrooms) to illustrate the range of potential parking demand. An estimate based on ITE Land Use Code 221 – Multifamily Housing (Mid- Rise) was also developed for comparison purposes, which is included in Table 4. The parking demand estimates include both the average and 85th percentile demand; the 85th percentile parking demand is the parking capacity needed to accommodate the peak parking demand experienced by 85% of users and is considered a conservative estimate. Based on the parking demand summary, the 85th percentile parking demand for the proposed affordable housing development is expected to range from 202 to 235 spaces, while the average parking demand ranges from 144 to 160 spaces. Based on the planned 240 parking supply and the peak parking demand (average of both variables), the proposed affordable housing development would have a 21-space parking surplus. Valley Station Apartments Traffic and Parking Review Site Generated Trips Figure 3 Legend AM Peak Hour Site TripsPM Peak Hour Site TripsADT Site TripsStop SignDirectional Distribution XXX(XXX)+XXX N 35%30% 35% 0 (0)3 (9)2 (4) 0 (0)18 (5)2 (3) 7 ( 3 ) 0 ( 0 ) 5 ( 2 ) 0 ( 0 ) 0 ( 0 ) 0 ( 0 ) 12 (5)27 (11) 0 ( 0 ) 1 0 ( 1 5 ) 0 ( 0 ) 4 ( 7 ) 0 (0)0 (0)8 (11) 0 (0)0 (0)6 (11) 2 0 ( 8 ) 0 ( 0 ) 1 7 ( 7 ) 0 ( 0 ) 0 ( 0 ) 0 ( 0 ) 5 ( 8 ) 0 ( 0 ) 5 ( 7 ) 0 ( 0 ) 1 3 ( 5 ) 1 4 ( 6 ) +305 +260 +3 0 5 +0 Valley Station Apartments Traffic and Parking Review Year 2028 Build Conditions Figure 4 91 (15)28 (93)28 (75) 34 (9)50 (29)13 (63) 3 0 ( 3 2 ) 5 7 ( 5 ) 1 8 ( 3 7 ) 8 ( 4 1 ) 9 ( 1 0 3 ) 8 ( 3 9 ) 0 (0)46 (158)8 (11) 0 (0)77 (93)6 (11) 2 0 ( 8 ) 0 ( 0 ) 1 7 ( 7 ) 0 ( 0 ) 0 ( 0 ) 0 ( 3 ) 27 ( 3 8 ) 32 ( 7 3 ) 86 ( 4 6 ) 78 ( 1 2 6 ) 2 8 ( 1 0 9 ) 4 0 ( 1 1 6 ) 3,000 2,425 2 , 8 7 5 1, 2 2 5 G a s l i g h t D r Ce d a r A v e ( C R 2 3 ) 153rd St 157th St 12 (5)27 (11) 9 3 ( 6 9 ) 1 0 ( 1 5 ) 4 6 ( 2 3 4 ) 4 ( 7 ) Legend AM Peak Hour VolumePM Peak Hour VolumeEstimated ADT VolumeStop Sign XXX(XXX)X,XXX N 155th St Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 9 Table 4 Parking Demand Summary Land Use (Variable) Size Rate (Average to 85th Percentile) Parking Demand (Average to 85th Percentile) Affordable Housing (Units) 144 units 1.00 to 1.40 spaces per unit 144 to 202 spaces Affordable Housing (Bedrooms) 290 bedrooms 0.55 to 0.81 spaces per bedroom 160 to 235 spaces Parking Demand (Average of both variables) 152 to 219 spaces Proposed Supply 240 spaces Surplus / (Deficit) 21 spaces Multifamily Housing (Units) 144 units 1.23 to 1.45 spaces per unit 177 to 209 spaces Multifamily Housing (Bedrooms) 290 bedrooms 0.78 to 0.88 spaces per bedroom 226 to 255 spaces Parking Demand (Average of both variables) 202 to 232 spaces Proposed Supply 240 spaces Surplus / (Deficit) 8 spaces Site Comparison To provide additional context, parking supply and demand was reviewed at similar Real Estate Equities apartment developments in the Twin Cities area. As shown in Table 5, comparable sites have an existing parking supply that ranges from 1.69 to 2.00 spaces per unit with an actual demand that ranges from 1.09 to 1.47 spaces per unit. The ITE 85th percentile parking demand estimated for the proposed development is 1.52 spaces per unit, which is at the higher end of the observed parking demand at comparable sites. The proposed development parking supply (1.67 spaces per unit) exceeds the actual demand at similar facilities, as well as the ITE estimated parking demand. Additional comparable sites, which include other workforce and market-rate developments, are provided in the Appendix. Table 5 Parking Supply / Demand Site Comparison Development Size Parking Supply Parking Demand Surplus / (Deficit) Supply (spaces) Ratio (spaces / unit) Demand (spaces) Ratio (spaces / unit) Arbor Court St. Louis Park, MN 114 units 207 1.82 158 1.40 49 Aster House Eagan, MN 204 units 344 1.69 253 1.30 91 Landing at Amber Fields Rosemount, MN 160 units 290 1.81 232 1.47 58 Spring House Coon Rapids, MN 168 units 336 2.00 219 1.34 117 Vista Point Mahtomedi, MN 110 units 192 1.75 112 1.09 80 Average Comparable 152 units 277 1.82 195 1.28 79 Proposed Development 144 units 240 1.67 219 1.52 21 Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 10 Parking Conclusion Based on the parking review, the proposed parking supply is expected to be able to accommodate the peak parking demand for the proposed development and no parking impacts to the adjacent roadway network are anticipated. The proximity of the Apple Valley Transit Station and other area retail land uses have the potential to further reduce the parking demand for the site. SITE PLAN A review of the proposed site plan does not indicate any major issues. However, the following items are offered for further consideration between area agencies and / or the project team. • Locate signage and landscaping to avoid creating any sight distance issues. • Review truck maneuverability to limit potential internal circulation conflicts. • Modify the internal crosswalk to ensure a perpendicular crossing / eliminate the crosswalk skew. 155TH STREET AND GASLIGHT DRIVE INTERSECTION A preliminary traffic signal and all-way stop warrant analysis was completed for the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection, which indicated that existing / future volumes are not close to meeting the criteria for a traffic signal or an all-way stop condition. Given the acceptable intersection operations and lack of crash history issues, no traffic control changes are needed at the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection. Detailed results are shown in the Appendix. Note that there is an existing crosswalk marked along the west approach of the intersection, but not the east approach. Based on the data collected, there were a total of 35 north-south pedestrians that crossed the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection between 6 a.m. and 7 p.m., with no more than seven (7) pedestrians on any north-south approach during any hour observed. Even with some increased pedestrian activity with the proposed development, there does not appear to be a need to provide an enhanced pedestrian crossing, such as a rectangular rapid flashing beacon (RRFP) at this time. In general, the east-west volumes along 155th Street are low enough to provide sufficient gaps for pedestrians to cross 155th Street. Preliminary review of the pedestrian crossing along the west side indicates that the current pedestrian ramps do not likely meet current ADA design standards. Therefore, the City should consider either removing the crosswalk marking and corresponding pedestrian signage along the west approach of the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection or provide improved pedestrian ramps and pavement markings to allow for consistent pedestrian crossings on all four (4) approaches of the intersection. Note that the City plans to conduct a pedestrian crossing review and recommend changes consistent with Dakota County’s Crossing Matrix. Valley Station Apartments Traffic and Parking Review August 20, 2025 Page 11 CONCLUSIONS Based on the findings of the study, the following conclusions are offered for consideration. 1) There does not appear to be any existing safety or crash issues at the 155th Street and Gaslight Drive / Apple Valley Transit Station intersection from a crash history perspective. 2) All study intersections and approaches operate at an acceptable LOS B or better during the typical weekday a.m. and p.m. peak hours; peak queues range between one (1) and two (2) vehicles. a. There are no significant existing intersection capacity issues in the study area. 3) The proposed development, which would replace the former Apple Valley Transit Station park-and- ride, is a 144-unit workforce housing apartment complex; there is planned to be 35 1-bedroom, 72 2-bedroom, and 37 3-bedroom units. The project was assumed to be open for residents in 2027. 4) Traffic forecasts were developed for year 2028 build conditions, which included a one (1.0) percent annual background growth and trip generation from the proposed development. a. The proposed development is expected to generate 102 a.m. peak hour (28 in / 74 out), 73 p.m. peak hour (43 in / 30 out), and 870 daily (435 in / 435 out) trips. 5) Under year 2028 build conditions, all study intersections and approaches are expected to continue to operate at LOS B or better during the typical weekday a.m. and p.m. peak hours; peak queues will also continue to generally range between one (1) and two (2) vehicles. a. There are no significant operational issues related to the proposed development from an intersection capacity perspective, and no additional infrastructure is needed to support the proposed development. 6) The proposed development is planning a total of 240 parking spaces, which includes 162 garage and 78 surface lot spaces; the proposed parking supply is expected to be able to accommodate the peak parking demand for the proposed development and no parking impacts to the adjacent roadway network are anticipated. 7) A review of the proposed site plan identified the following considerations: a. Locate signage and landscaping to avoid creating any sight distance issues. b. Review truck maneuverability to limit potential internal circulation conflicts. c. Modify the internal crosswalk to ensure a perpendicular crossing / eliminate the crosswalk skew. 8) 155th Street and Gaslight Drive / Apple Valley Transit Station intersection considerations: a. Given the acceptable intersection operations and lack of crash history issues, no traffic control changes are needed. b. Preliminary review of the pedestrian crossing along the west side of the intersection indicates that the current pedestrian ramps do not likely meet current ADA design standards; the City should consider either removing the crosswalk marking and corresponding pedestrian signage along the west approach of the intersection or provide improved pedestrian ramps and pavement markings to allow for consistent pedestrian crossings on all four (4) approaches of the intersection. The City plans to conduct a pedestrian crossing review and recommend changes consistent with Dakota County’s Crossing Matrix. c. There does not appear to be a need to provide an enhanced pedestrian crossing, such as a rectangular rapid flashing beacon (RRFP) at this time. APPENDIX Time Left Turns Through Right Turns Peds/Bikes Time Left Turns Through Right Turns Peds/Bikes 12 - 1 AM 12 - 1 AM 1 - 2 AM 1 - 2 AM 2 - 3 AM 2 - 3 AM 3 - 4 AM 3 - 4 AM 4 - 5 AM 4 - 5 AM 5 - 6 AM 5 - 6 AM 6 - 7 AM 81 15 19 6 - 7 AM 5 27 32 7 - 8 AM 88 24 25 7 - 8 AM 11 31 33 8 - 9 AM 21 20 30 8 - 9 AM 15 34 3 9 - 10 AM 3 20 27 9 - 10 AM 15 21 0 10 - 11 AM 11 37 34 10 - 11 AM 34 28 1 11 - 12 PM 7 37 56 11 - 12 PM 26 25 1 12 - 1 PM 7 47 57 12 - 1 PM 28 42 3 1 - 2 PM 9 62 72 1 - 2 PM 45 27 1 2 - 3 PM 5 42 69 2 - 3 PM 38 16 0 3 - 4 PM 11 43 77 3 - 4 PM 39 31 0 4 - 5 PM 4 77 64 4 - 5 PM 48 30 5 5 - 6 PM 19 69 64 5 - 6 PM 54 22 7 6 - 7 PM 12 44 70 6 - 7 PM 41 31 1 7 - 8 PM 7 - 8 PM 8 - 9 PM 8 - 9 PM 9 - 10 PM 9 - 10 PM 10 - 11 PM 10 - 11 PM 11 - 12 AM 11 - 12 AM 1,479 0 851 0 Time Left Turns Through Right Turns Peds/Bikes Time Left Turns Through Right Turns Peds/Bikes 12 - 1 AM 12 - 1 AM 1 - 2 AM 1 - 2 AM 2 - 3 AM 2 - 3 AM 3 - 4 AM 3 - 4 AM 4 - 5 AM 4 - 5 AM 5 - 6 AM 5 - 6 AM 6 - 7 AM 8 54 4 6 - 7 AM 3 9 9 7 - 8 AM 22 55 13 7 - 8 AM 8 9 8 8 - 9 AM 15 18 24 8 - 9 AM 2 6 7 9 - 10 AM 22 2 29 9 - 10 AM 1 2 3 10 - 11 AM 22 5 33 10 - 11 AM 0 2 6 11 - 12 PM 23 5 36 11 - 12 PM 2 4 3 12 - 1 PM 36 1 38 12 - 1 PM 5 19 6 1 - 2 PM 46 4 39 1 - 2 PM 2 6 9 2 - 3 PM 26 3 38 2 - 3 PM 8 18 8 3 - 4 PM 30 2 35 3 - 4 PM 20 38 15 4 - 5 PM 28 6 28 4 - 5 PM 23 68 25 5 - 6 PM 30 5 38 5 - 6 PM 34 69 33 6 - 7 PM 36 4 30 6 - 7 PM 19 30 18 7 - 8 PM 7 - 8 PM 8 - 9 PM 8 - 9 PM 9 - 10 PM 9 - 10 PM 10 - 11 PM 10 - 11 PM 11 - 12 AM 11 - 12 AM 893 0 557 0 Traffic Signal Warrant Analysis Total Vehicles (unadjusted) Total Vehicles (unadjusted) 155th Street (Major Street) Volume Gaslight Drive (Minor Street) Volume Eastbound Volume by Hour Total Vehicles (unadjusted) Westbound Volume by Hour Total Vehicles (unadjusted) Northbound Volume by Hour Southbound Volume by Hour Project Name Project/File # Scenario Major Street (E/W Road) Minor Street (N/S Road) Analyzed with Analyzed with Total Approach Volume Total Approach Volume Total Ped/Bike Volume Total Ped/Bike Volume Right turn reduction of Right turn reduction of No high speed or isolated community reduction applied to the Volume Warrant thresholds. Traffic Signal Warrant Analysis Required values reached for 0 total, minor, 0 delay 0 hours Condition Satisfied?Not Satisfied Not Satisfied Criteria - Total Approach Volume (veh in one hour)800 See Figure BelowCriteria - Minor Street High Side Volume (veh in one hour)150 Criteria - Minor Street High Side Delay (veh-hrs)5 * Should be applied only after an adequate trial of other alternatives that could cause less delay and inconvenience to traffic has failed to solve the traffic problems. Not Satisfied 0 hours Condition Satisfied? Required values reached for Warrant 3, Peak Hour Vehicular Volume Warrants 1 - 3 (Volume Warrants) Valley Station Apartments Traffic Review 25-217 Existing Conditions Intersection Information Condition Satisfied?Not Satisfied Not Satisfied Not Satisfied 155th Street Gaslight Drive 1 approach lane 1 Approach Lane 0 percent applied 0 percent applied Warrant 1, Eight Hour Vehicular Volume Condition A Condition B Condition A+B* 2330 vehicles 1450 vehicles 0 crossings 0 crossings 500 750 400 (Cond. A) & 600 (Cond. B) Criteria - Minor Street (veh/hr)150 75 120 (Cond. A) & 60 (Cond. B) Figure 4C-1 (Warrant 2) & Figure 4C-3 (Warrant 3) Condition A Condition B See Figure BelowCriteria Warrant 2, Four Hour Vehicular Volume Required values reached for 0 hours 0 hours 0 (Cond. A) & 0 (Cond. B) Criteria - Major Street (veh/hr) 0 100 200 300 400 500 600 700 800 900 1,000 0 500 1000 1500 2000 2500 Mi n o r S t r e e t V o l u m e ( H i g h A p p r o a c h O n l y ) Major Street Volume (Both Approaches) Warrant 2 Threshold Warrant 3 Threshold Intersection Volumes Project Name Project/File # Scenario Major Street (E/W Road) Minor Street (N/S Road) Analyzed with Analyzed with Total Approach Volume Total Approach Volume Total Ped/Bike Volume Total Ped/Bike Volume Right turn reduction of Right turn reduction of No high speed or isolated community reduction applied to the Multi-Way Stop Warrant thresholds. Criteria - Minor Street (total vol-veh, ped, & bikes/hr) 160 for the same 8 hours of an average day Criteria - Crash Experience 4 or more correctable crashes in 12-month period Criteria - Delay (average sec/veh) 24 during the highest hour Required values reached for 0 hours, crashes, & sec. average delay/veh Criteria - Major Street (veh/hr) 240 for any 8 hours of an average day Criteria - Minor Street (total vol-veh, ped, & bikes/hr) 200 for the same 8 hours of an average day Criteria - Delay (average sec/veh) 30 during the highest hour Condition D - Combination Volume, Crash Experience, & Delay Condition Satisfied? Required values reached for correctable crashes Criteria - Crash Experience 5 or more correctable crashes in 12-month period Not Satisfied Condition C - Intersection Volume & Delay Condition Satisfied?Not Satisfied Required values reached for 0 hours & sec. average delay/veh Criteria - Major Street (veh/hr) 300 for any 8 hours of an average day Condition Satisfied?Not Satisfied Criteria* Traffic Signal Warranted & Justified * Multi-way stop control may be used as an interim measure that can be installed quickly to control traffic while arrangements are being made for the installation of the traffic control signal. Condition B - Crash Experience Condition Satisfied?Not satisfied Traffic Signal Warrant Analysis Multi-Way Stop Warrants Valley Station Apartments Traffic Review 25-217 Existing Conditions Intersection Information 155th Street Gaslight Drive 1 approach lane 1 Approach Lane 2330 vehicles 1450 vehicles 0 crossings 0 crossings 0 percent applied 0 percent applied Condition A - Traffic Signal Warrant ITEM: 6.A. MEETING DATE: September 3, 2025 SECTION: Other Business Description: Review of Upcoming Schedule and Other Updates Planning Commission - Wednesday, September 17, 2025 - 7:00 p.m. Planning Commission - Wednesday, October 1, 2025 - 7:00 p.m. City Council - Thursday, September 11, 2025 - 7:00 p.m. City Council - Thursday, September 25, 2025 - 7:00 p.m. Staff Contact: Breanna Vincent, Department Assistant Department / Division: Community Development Action Requested: N/A Summary: Next Planning Commission Meetings: Wednesday, September 17, 2025 - 7:00 p.m. Applications due by 9:00 a.m. on Wednesday, August 20, 2025. Wednesday, October 1, 2025 - 7:00 p.m. Applications due by 9:00 a.m. on Wednesday, September 3, 2025. Next City Council Meetings: Thursday, September 11, 2025 - 7:00 p.m. Thursday, September 25, 2025 - 7:00 p.m. Background: N/A Budget Impact: N/A Attachments: None